IMPORTANT SAFETY INSTRUCTIONS

 NOTE:

The power supply cord with this air 

conditioner contains a current detection 

device designed to reduce the risk 

of fire. Please refer to the section 

“Operation of Current Device” (below) 

for details. In the event that the power 

supply cord is damaged, it cannot be 

repaired. It must be replaced by an 

authorized repair technician with a cord 

from the Product Manufacturer.

WARNING

Avoid fire hazards or electric shock.  

DO NOT 

use an extension cord or an 

adapter plug. 

DO NOT

 remove any prong 

from the power cord.

OPERATION OF  

CURRENT DEVICE:

The power supply cord contains a 

current device that senses damage 

to the power cord. To test your power 

supply cord, do the following: 

1.  Plug in the air conditioner.

2.  The power supply cord will have 

TWO buttons on the plug head. Press 

the TEST button. You will notice a 

click as the RESET button pops out.

3.  Press the RESET button. Again,  

you will notice a click as the  

button engages.

4.  The power supply cord is now 

supplying electricity to the unit. (On 

some products this is also indicated 

by a light on the plug head.)

WARNING

FOR YOUR SAFETY: Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other appliances.

WARNING - PREVENT ACCIDENTS

To reduce the risk of fire, electrical shock, or injury to persons when using 

your air conditioner, follow basic precautions, including the following: 

●  Be sure the electrical service is adequate for the model you have 

chosen. This information can be found on the serial plate, which is 

located on the side of the cabinet and behind the grille.

●  If the air conditioner is to be installed in a window, you will probably 

want to clean both sides of the glass first. If the window is a triple-

track type with a screen panel included, remove the screen completely 

before installation.

●  Be sure the air conditioner has been securely and correctly installed 

according to the installation instructions in this manual.

●  Save this manual for possible future use in removing or installing this unit.

●  When handling the air conditioner, be careful to avoid cuts from sharp 

metal fins on front and rear coils.

WARNING - ELECTRICAL INFORMATION

The complete electrical rating of your new room air conditioner is stated 

on the serial plate. Refer to the rating when checking the electrical 

requirements.

●  Be sure the air conditioner is properly grounded. To minimize shock 

and fire hazards, proper grounding is important. The power cord is 

equipped with a three-prong grounding plug for protection against 

shock hazards. 

●  Your air conditioner must be used in a properly grounded wall 

receptacle. If the wall receptacle you intend to use is not adequately 

grounded or protected by a time delay fuse or circuit breaker, have a 

qualified electrician install the proper receptacle.

●  Ensure the receptacle is accessible after the unit installation.

● 

DO NOT

 run air conditioner without side protective cover in place. This 

could result in mechanical damage within the air conditioner.

● 

DO NOT

 use an extension cord or an adapter plug.

 NOTE:

DO NOT

 use the plug to turn the unit on or off.

●  Always make sure the RESET button is pushed in for correct operation.

●  The power supply must be replaced if it fails reset when either the TEST 

button is pushed or it cannot be reset.

●  If power supply cord is damaged, it cannot be repaired. Please call 

Consumer Services at 844-472-2473 to assist with replacement.

NOTE:

 This air conditioner is designed to be operated under the

following conditions:

Cooling 

Operation

Outdoor Temp:

64 – 109°F/18 – 43°C

(64 – 125°F/18 – 52°C for special tropical models)

Indoor Temp:

62 – 90°F/17 – 32°C

Performance may be reduced outside of these operating temperatures.

Grounding Type

Wall Receptacle

Do not, under any 

circumstances, cut, 

remove, or bypass the 

ground prong.

Power supply cord  

with 3-prong grounding 

plug and current 

detection device

Содержание 3PASC10000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 3PASC10000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...nce of this unit Contact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be superv...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Страница 7: ...l CASEMENT window Modification may be necessary when installing in windows made differently than those shown in these instructions INSTALLATION TIPS For wood frame casement windows It may be necessary...

Страница 8: ...room s you wish to cool Remember it is difficult to move air around corners Also choose a window that is within 6 feet of an electrical outlet See Electrical Information on Page 3 DO NOT USE AN EXTEN...

Страница 9: ...r of seal strip should coincide with the line marked in Step 2 The two screw holes drilled in Step 3 should be directly above seal strip in the inner track Fig 5 STEP 5 SECURELY ATTACH A SIDING PROTEC...

Страница 10: ...tooth saw Remove any burrs with a file STEP 11 FASTEN SIDE CHANNELS Fasten the side channels to the sides of the unit using 3 screws Item 17 page 4 per channel Start with first screw at top of channe...

Страница 11: ...screws Fig 13 STEP 17 HOOK THE SAFETY BRACKET The safety bracket should be hooked over the base of the unit and fastened to the front of the platform assembly Use a self threading screw Fig 14 NOTE Th...

Страница 12: ...rm will rest properly and allow the proper slope 5 16 inch lower on outside Fig 1 NOTE If you are planning to use a siding protection board See Step 6 on the outside of your house hold the board in pl...

Страница 13: ...e plastic window panel between a board and a work table and cut along the cutting line with a fine tooth saw Remove any burrs with a file STEP 9 FASTEN THE SIDE CHANNELS TO THE SIDE OF THE UNIT Using...

Страница 14: ...ndow jamb with two inch self threading screws If additional holding is necessary two screws may be used on the sides of the panel frame as well STEP 15 DRILL SCREW CLEARANCE HOLES Drill two screw clea...

Страница 15: ...unit This unit can be controlled by the unit control or with the remote control FOLLOW ME Indicator Energy Saver Mode Sets Mode Sleep Mode Turns Unit On or Off Sets Fan Speed Adjusts Temp or Time Exha...

Страница 16: ...t will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO only AUTO COOLING and AUTO FAN modes TO OPERATE AUT...

Страница 17: ...til the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly After unit is...

Страница 18: ...e unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened...

Страница 19: ...coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room...

Страница 20: ...151 Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_3...

Отзывы: