Perfect Aire 3PASC10000 Скачать руководство пользователя страница 16

13

 SLEEP FEATURE:

Press the   SLEEP button to initiate SLEEP 

mode. In this mode, the selected temperature will 

increase by 2°F (1°C) 30 minutes after the mode is 

selected. The temperature will then increase (cooling) 

or decrease (units with heating only) by another 

2°F (1°C) after an additional 30 minutes. This new 

temperature will be maintained for 6 hours before it 

returns to the originally selected temperature. This 

ends the SLEEP mode and the unit will continue 

to operate as originally programmed. The SLEEP 

mode program can be canceled at any time during 

operation by pressing the SLEEP button again.

 CHECK FILTER FEATURE:

Press the   CHECK FILTER button to initiate this 

feature. This feature is a reminder to clean the Air 

Filter for more efficient operation. The LED (light) will 

illuminate after 250 hours of operation. To reset after 

cleaning the filter, press the CHECK FILTER button 

and the light will go off.

 ENERGY SAVER FEATURE:

Press the   ENERGY SAVER button to initiate this 

function. This function is available on COOL, DRY 

and AUTO (only AUTO-COOLING and AUTO-FAN) 

modes. In this mode, the fan will continue to run for 3 

minutes after the compressor shuts off. The fan then 

cycles on for 2 minutes, at 10 minute intervals, until 

the room temperature is above the set temperature, 

at which time the compressor turns back on and 

cooling starts.

 FOLLOW ME FEATURE:

This feature can ONLY be activated 

from the remote control. The 

remote control serves as a remote 

thermostat allowing for precise 

temperature control at its location.

To activate the Follow Me feature, point the remote 

control toward the unit and press the FOLLOW ME 

button. The remote displays the actual temperature 

at its location. The remote control will send this 

signal to the air conditioner every 3 minutes until the 

FOLLOW ME button is pressed again. If the unit does 

not receive the Follow Me signal during any 7 minute 

interval, the unit will beep to indicate use of the 

Follow Me feature has ended. The actual temperature 

can be displayed at the unit by pressing the FAN only 

mode. When in the COOL mode, the unit display 

indicates the set temperature.

 TO SELECT THE OPERATING MODE:

To choose operating mode, press the   MODE 

button. Each time you press the button, a mode is 

selected in a  sequence that goes from AUTO, COOL, 

DRY and FAN. The indicator light will be illuminated 

and remain on once the mode is selected. 

The unit 

will automatically initiate the Energy Saver function 

under COOL, DRY, and AUTO (only AUTO-COOLING and 

AUTO-FAN) modes.
TO OPERATE AUTO FEATURE: 

When you set the air conditioner in AUTO mode, it 

will automatically select cooling or fan only operation 

depending on what temperature you have selected 

and the room temperature. The air conditioner will 

automatically control room temperature around the 

temperature you set. 

In this mode, the fan speed 

cannot be adjusted. 

It starts automatically at a speed 

according to the room temperature. If the room does 

not get too warm, it will stay at a “Low” speed.

TO OPERATE FAN ONLY: 

Use this function (   ) only when cooling is not 

desired, such as for room air circulation or to exhaust 

stale air. (Remember to open the vent during this 

function, but keep it closed during cooling for 

maximum cooling efficiency.) You can choose any 

fan speed you prefer. During this function, the display 

will show the actual room temperature, not the set 

temperature as in the cooling mode. Temperature 

cannot be adjusted in the FAN only mode.

TO OPERATE DRY MODE: 

In this mode, the air conditioner will reduce air 

humidity. If the space is a closed or sealed area, 

some degree of cooling will continue.

 TIMER: AUTO START/STOP FEATURE:

●  When the unit is on or off, first press the   

TIMER button. The TIMER ON indicator light 

illuminates and indicates the Auto Start program  

is initiated.

●  When the time of TIMER ON is displayed, pressing 

the TIMER button again illuminates the TIMER 

OFF indicator light and indicates the Auto Stop 

program is initiated.

●  Press or hold the UP or DOWN button to change 

the Auto time by 0.5 hour increments, up to 10 

hours, then by 1 hour increments, up to 24 hours. 

The control will count down the time remaining 

until start.

●  The selected time will register in 5 seconds and 

the system will automatically revert back to 

displaying the previous temperature setting or the 

room temperature (depending on whether the unit 

is powered on or off and the mode it is in).

●  Turning the unit ON or OFF at any time or 

adjusting the timer setting to 0.0 will cancel the 

Auto Start/Stop program.

A NOTE ABOUT THE TIMER:

 When you set the timer, the 

unit will only go on once and off once. If you want the 

air conditioner to cycle on and off based on desired 

room temperature, you do not need to set the timer. 

Instead, set your desired temperature and the unit will 

cycle on and off based on that temperature setting.

Light

Flashing

Follow Me

Содержание 3PASC10000

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 3PASC10000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...nce of this unit Contact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be superv...

Страница 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Страница 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Страница 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Страница 7: ...l CASEMENT window Modification may be necessary when installing in windows made differently than those shown in these instructions INSTALLATION TIPS For wood frame casement windows It may be necessary...

Страница 8: ...room s you wish to cool Remember it is difficult to move air around corners Also choose a window that is within 6 feet of an electrical outlet See Electrical Information on Page 3 DO NOT USE AN EXTEN...

Страница 9: ...r of seal strip should coincide with the line marked in Step 2 The two screw holes drilled in Step 3 should be directly above seal strip in the inner track Fig 5 STEP 5 SECURELY ATTACH A SIDING PROTEC...

Страница 10: ...tooth saw Remove any burrs with a file STEP 11 FASTEN SIDE CHANNELS Fasten the side channels to the sides of the unit using 3 screws Item 17 page 4 per channel Start with first screw at top of channe...

Страница 11: ...screws Fig 13 STEP 17 HOOK THE SAFETY BRACKET The safety bracket should be hooked over the base of the unit and fastened to the front of the platform assembly Use a self threading screw Fig 14 NOTE Th...

Страница 12: ...rm will rest properly and allow the proper slope 5 16 inch lower on outside Fig 1 NOTE If you are planning to use a siding protection board See Step 6 on the outside of your house hold the board in pl...

Страница 13: ...e plastic window panel between a board and a work table and cut along the cutting line with a fine tooth saw Remove any burrs with a file STEP 9 FASTEN THE SIDE CHANNELS TO THE SIDE OF THE UNIT Using...

Страница 14: ...ndow jamb with two inch self threading screws If additional holding is necessary two screws may be used on the sides of the panel frame as well STEP 15 DRILL SCREW CLEARANCE HOLES Drill two screw clea...

Страница 15: ...unit This unit can be controlled by the unit control or with the remote control FOLLOW ME Indicator Energy Saver Mode Sets Mode Sleep Mode Turns Unit On or Off Sets Fan Speed Adjusts Temp or Time Exha...

Страница 16: ...t will be illuminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO only AUTO COOLING and AUTO FAN modes TO OPERATE AUT...

Страница 17: ...til the desired Left Right direction is obtained ADDITIONAL THINGS YOU SHOULD KNOW The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly After unit is...

Страница 18: ...e unit without the air filter CABINET CLEANING Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened...

Страница 19: ...coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the room...

Страница 20: ...151 Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_3...

Отзывы: