INSTALLATION INSTRUCTIONS
SITE INSTRUCTIONS
SITE FOR INSTALLING INDOOR UNIT
• Where there is no obstacle near the air outlet
and air can be easily blown to every corner.
• Where piping and wall hole can be easily
arranged.
• Keep the required space from the unit to the
ceiling and wall according to the installation
diagram on previous page.
• Where the air filter can be easily removed.
• Keep the unit and remote control 3.28ft(1m) or
more apart from television, radio etc.
• Keep as far as possible from fluorescent lamps.
• Do not put anything near the air inlet to
obstruct it from air absorption.
• Install on a wall that is strong enough to bear
the weight of the unit.
• Install in a place that will not increase operation
noise and vibration.
• Keep away from direct sunlight and heating
sources. Do not place flammable materials or
combustion apparatuses on top of the unit.
SITE FOR INSTALLING OUTDOOR UNIT
• Where it is convenient to install and well
ventilated.
• Avoid installing it where flammable gas
could leak.
• Keep the required distance apart from the wall.
• Keep the outdoor unit away from greasy dirt,
vulcanization gas exit.
• Avoid installing it by the roadside where there
is a risk of muddy water.
• A fixed base where it is not subject to
increased operation noise.
• Where there is not any blockage of the air outlet.
• Avoid installing under direct sunlight, in an aisle
or sideway, or near heat sources and ventilation
fans. Keep away from flammable materials,
thick oil fog, and wet or uneven places.
• In case the pipe length is more than 24.6ft(7.5m),
the refrigerant should be charged additionally,
according to below table.
model
required
amount
of
additional
refrigerant
oz
/
ft
9K-18K
0.22
24K
0.32
30K-36K
0.43
Indoor unit
Outdoor unit
Indoor unit is higher than outdoor unit
Pipe length is
65.4ft(20m) Max.
Height should b
e
less than 32.8f
t(10m)
Indoor unit
Outdoor unit
Outdoor unit is higher than indoor unit
Pipe length is
65.4ft(20m) Max.
Height should b
e
less than 16.4f
t(5m)
If the height or pipe length is out of the scope of
the table, please consult the merchant.
(Continued)
INSTALLATION INSTRUCTIONS
(Continued)
• Decide an installing location for the mounting
plate according to the indoor unit location and
piping direction.
NOTE:
It is recommended to install screw
anchors for sheet rock, concrete block, brick
and such type of wall.
• Keep the mounting plate horizontal with a
horizontal level or dropping line.
• Mark the center of the indoor unit on mounting
plate for future reference.
NOTE:
The center of the mounting bracket
may not be the center of the indoor unit.
INDOOR UNIT INSTALLATION
1. INSTALLING THE MOUNTING PLATE
• Install mounting plate to the wall with a
minimum of six screws, evenly spaced to
properly support indoor unit weight.
NOTE:
The shape of your mounting plate
may be different from the one above, but the
installation method is similar.
MOUNTING BRACKET DIAGRAMS AND DIMENSIONS
(Recommended)
MOUNTING PLATE INSTRUCTIONS
For 30k-36k Models, WIDTH: 32.3in/820mm
7.9in/200mm or more to ceiling
Indoor unit outline
Pipe hole
2in/50mm
or more to wall
2in/50mm
or more to wall
For 908/1080 Series Model, WIDTH: 24.8in/629mm
7.9in/200mm or more to ceiling
Indoor unit outline
Pipe hole
2in/50mm
or more to wall
2in/50mm
or more to wall