background image

3

When removing air filter, do not 

touch metal parts of the unit.

Doing so may cause an injury.

.

Cleaning unit when power is ON 

may cause fire and electric shock

and may cause an injury. 

Operation with windows open may

cause moisture to enter the room.

 

 

 

 

Stop operation and close the

window in severe storms or 

hurricanes.

Do not clean with water.

Water may enter the unit and 

degrade the insulation causing an 

electric shock.

This could injure the pet or plant.

Failure to do so may cause electric

shock and damage.

Do not put a pet or house plant 

where it will be exposed to 

direct air flow.

Hold the plug by the head of the

power plug when taking it out.

Ensure proper ventilation 

especially in rooms with a stove 

or other appliances.

Failure to do so may result in an

oxygen shortage.

This unit is NOT intended to 

preserve precision devices, food, 

pets, plants, and art objects. It may

cause deterioration of quality, etc.

Leaving power on may cause unit 

failure or fire.

Use only as intended.

If unit will not be used for a long

period of time, turn OFF main 

power switch.

 

 

 

 

 

 

If water enters the unit, turn the unit off at the power 

outlet and switch off the circuit breaker. Isolate supply

by taking the power-plug out and contact a qualified 

serviced technician. 

Obstacles may cause appliance 

failure or accident.

Cleaners or detergents may change 

the color or scratch the surface of

the unit.

Do not place obstacles around 

air-inlets or inside of air-outlet.

Use only a soft cloth to clean

the unit.

Prolonged exposure to outdoor

elements may cause damage to

installation bracket causing unit to fall.

There is danger of electric shock.

Periodically check installation

bracket for damage.

.

Operation without secured filters

may cause failure. A dirty filter 

can cause the unit to not run efficiently.

Water from unit contains 

contaminants and could cause 

illness.

Always insert the filters securely. 

Clean filter AT LEAST once 

every two weeks.

NEVER drink water drained from

air conditioner.

Unit and Circuit breaker/fuse

must be switched OFF when

cleaning. 

Do not place heavy objects on the power cord 

and always ensure that the cord is not 

compressed.

Use caution when unpacking 

and installing. 

Sharp edges could cause injury.

!

!

!

!

!

!

!

!

!

!

!

There is danger of fire or electric shock.

!

CAUTION

 

Electrical Shock and 

Personal Injury Hazard

 

Meeting Electrical Requirements

WARNING

!

• Electrical ground is required on this appliance.

• DO NOT ground  to a gas line.

• If cold water pipe is interrupted by using plastic, non-

metallic gaskets, or other insulating materials. DO NOT use 

for grounding.

• Check with a qualified electrician if you are in doubt as to 

whether the appliance is properly grounded.

• DO NOT modify power supply cord plug. If it does not fit the 

outlet, have a proper outlet installed by a qualified electrician.

• DO NOT have a fuse in the neutral or grounding circuit. 

A fuse in the neutral, or grounding circuit could result in an 

electrical shock.

• DO NOT use an extension cord with this appliance.

Failure

 

to

 

follow these instructions could result 

in electrical shock, serious injury, or death.

Observe all local governing codes and ordinances.

Do not, under any circumstances, remove the power

supply cord grounding prong.

NOTE: 

If codes permit, and a separate grounding wire is used,

it is recommended that a qualified electrician determine that the

grounding path is adequate and not interrupted by plastic, 

non-metallic gaskets, or other insulating materials.

Receptacle Wiring

Receptacle wiring should be a minimum of 14 gauge. Use copper 

wire only. It is your responsibility to provide proper and adequate

receptacle wiring, installed by a qualified electrician.

Electrical Requirements

A time delay fuse or time delay circuit breaker is also required. A

separate circuit, serving only this appliance, MUST be provided.  

Содержание 3PACH18000

Страница 1: ...for future reference along with your receipt Your Source for Home Comfort WINDOW AIR CONDITIONER USER MANUAL 17 700 18 500 25 000 28 000 BTU FOR MODELS 3PAHP18002 with 11 200 BTU heat pump 3PACH18000...

Страница 2: ...The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditioner Disabled persons may req...

Страница 3: ...se explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may caus...

Страница 4: ...from unit contains contaminants and could cause illness Always insert the filters securely Clean filter AT LEAST once every two weeks NEVER drink water drained from air conditioner Unit and Circuit b...

Страница 5: ...breaker have a qualified electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation Do not run air conditioner without side protective cover in place Thi...

Страница 6: ...e similar AIR CONDITIONER FEATURES Before you begin thoroughly familiarize yourself with the control panel as shown below and all its functions Then follow the symbol for the functions you desire The...

Страница 7: ...mode When in the Cool mode the unit display indicates the set temperature This feature can ONLY be activated from the remote control The remote control serves as a remote thermostat allowing for prec...

Страница 8: ...delayed start if the unit is turned off and on quickly After unit is turned off leave unit off for a minimum of 3 minutes before attempting to turn back on This prevents overheating of the compressor...

Страница 9: ...p these instructions for future reference Note to Installer Be sure to leave these instructions with the Consumer Completion time Approximately 1 hour Skill level Installation of this appliance requir...

Страница 10: ...drapes or blinds will not stop proper airflow 5 Check the available electrical service Power supply MUST be the same as that shown on the unit serial nameplate Power cord is 48 inches long Be sure you...

Страница 11: ...ts to holes in top of cabinet where shipping screws were removed from See Fig 6 0 Your unit may come with internal packaging This packaging MUST be removed prior to installing the air conditioner back...

Страница 12: ...k center of window sill See Fig 10 2 Place cabinet in window with bottom sill angle firmly seated over window sill as shown See Fig 10A Bring window down temporarily behind top angle to hold cabinet i...

Страница 13: ...refully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation of front is the reverse of re...

Страница 14: ...frame construction at ends of windows under truss bearing points etc can be installed stud nearest the center of area where air conditioner thickness of framing material used thickness of framing mate...

Страница 15: ...ction refer to Step 2 of Thru The Wall Installation for wall thickness greater than 8 1 2 2 Secure cabinet in place using masonry nails or the right masonry anchor screws Another way to do this is to...

Страница 16: ...the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or with a cloth dampened in a solution of warm water and mild liquid dishwashing deterge...

Страница 17: ...re and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time cooling To defrost the coil set to Fan Only mode Then set temperature to a higher setting UNIT WILL NO...

Страница 18: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...