background image

10

CONTROL PANEL

 USING THE CONTROL PANEL

COOL Mode

•  Press the MODE button until the COOL indicator is on.

•  Press the TEMP/TIME buttons (+/–) to adjust desired 

room temperature on the display.

•  Press the SPEED button to select desired fan speed 

(High, Med, Low, Auto).

HEAT Mode

•  Press the MODE button until the HEAT indicator is on.

•  Press the TEMP/TIME buttons (+/–) to adjust desired 

room temperature on the display.

•  Press the SPEED button to select desired fan speed 

(High, Med, Low, Auto).

FAN Mode

Use this mode to circulate the air in the room without 

cooling or dehumidifying the room. In FAN mode, the 

temperature cannot be adjusted.

•  Press the mode button until the FAN indicator is on.

•  Press the SPEED button to adjust the fan speed (High, 

Med, Low). When using the control panel, AUTO fan 

speed cannot be selected. AUTO fan speed can be 

selected with the remote only.

ENERGY SAVER Mode

While the unit is running press the MODE button to select 

ENERGY SAVER. When the set temperature is reached 

the compressor will shut off. The fan will continue to run 

3 minutes after the compressor shuts off. The unit will not 

run for 10 minutes. After 10 minutes the fan will run for 1 

minute and repeat the cycle. If the temperature changes, the 

compressor will turn on until the set temperature is reached.

TIMER ON/OFF Function
  TIMER ON

•  Turn the unit on to set the desired temperature and fan 

speed for when the unit turns on with the Timer.

•  Turn the unit off (Standby).

•  Press the TIMER button

•  Press the TEMP/TIMER buttons (+/–) to set the time on 

the display from 0.5–24 hours (by 0.5 hour  increments up 

to 24 hours).

•  The TIMER ON/OFF indicator will be on when the timer 

has been set.

  TIMER OFF

•  Turn the unit on to set the desired temp. and fan speed.

•  Press the TIMER button.

•  Press the TEMP/TIMER buttons (+/–) to set the time on 

the display from 0.5–24 hours (by 0.5 hour increments up 

to 24 hours).

•  The TIMER ON/OFF indicator will be on when the timer 

has been set.

NOTE:  

To cancel the timer function press the TIMER button again.

Lights next to the touch pads on the unit's 

control panel indicate the selected settings.
The display shows the set temperature when 

in HEAT/COOL/ENERGY SAVER modes. The 

display shows time remaining on the delay timer. 

It shows the room temp. when in FAN only mode.

1. POWER Button 

Press to turn the unit ON/OFF.

2.  REMOTE CONTROL SIGNAL RECEIVER 

• Make sure signal receiver is unobstructed. 

• Maximum remote distance is 26 ft. 

• Unit will beep when signal from remote has  

  been received.

3.  DIGITAL DISPLAY 

• In FAN mode, this displays the room temp. 

• In COOL and HEAT mode, this displays the  

  set temperature. 

• In TIMER function, On/Off time is displayed. 

• If Display shows Error Codes, contact 

  Consumer Services at 844-472-2473.

4. SET Indicator 

Light indicates the unit is in the temperature or 

delay time set mode.

5. TEMP/TIMER B/– 

• Press to adjust the temperature and set the  

  time for the On or Off timer.  

• Press both + and – at the same time to  

  switch between °C and °F.

6.  TIMER ON/OFF Indicator 

Illuminates when timer has been set for On 

and/or Off.

7. TIMER Button 

Press to set the timer On/Off.

8. MODE Button 

Press to select HEAT, COOL, ENERGY SAVER 

or FAN.

9.  FAN SPEED Button 

Press to select LOW, MED, HIGH or AUTO  

fan speed.

Set

+

-

TIMER

MED

HIGH

LOW

AUTO

POWER

FAN

SPEED

MODE

COOL
ENERGY SAVER
FAN ONLY

HEAT

0.5-24 HR

TEMP/TIMER

1

2

5

7

6

3

4

8

9

Содержание 2PAHP12002

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 2PAHP12002 WITH HEAT PUMP Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...aintenance of this unit Contact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be...

Страница 4: ...om the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so...

Страница 5: ...d of time un plug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure o...

Страница 6: ...tioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling th...

Страница 7: ...ging Airflow Direction Airflow on unit may be diverted left or right from center by louvers Upward and downward air discharge is provided by tilting louvers Adjust tilt louvers for desired airflow dir...

Страница 8: ...must be outdoors not inside a building or garage Inner sill Offset Window Sill Exterior Interior wall 27 39 16 min Sash Check the location where the unit will be installed Proper installation is your...

Страница 9: ...packing foam from inside of unit Handle NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material WARNING DO NOT operate unit with...

Страница 10: ...and bottom slots of accordion Screw accordion to the top and bottom holes in air conditioner cabinet NOTE Some accordion panels may have 2 slots at each end You will be able to see a mounting hole thr...

Страница 11: ...URING ACCORDION TO THE WINDOW FRAME 1 Pull left hand accordion panel out until it reaches the window frame Use a 3 32 drill bit to drill a starter hole through the hole in the accordion panel housing...

Страница 12: ...out Condensate Drain Cup 1 2 Diameter Hose Outer Case 1 Insert air conditioner into cabinet 2 Install shipping screws on both sides of cabinet 3 Plug the control panel to the unit 4 Insert front tabs...

Страница 13: ...crements up to 24 hours The TIMER ON OFF indicator will be on when the timer has been set TIMER OFF Turn the unit on to set the desired temp and fan speed Press the TIMER button Press the TEMP TIMER b...

Страница 14: ...DO NOT place the remote where it is exposed to direct sunlight or strong lights DO NOT drop anything on the remote as this may cause damage DO NOT block the area between the unit and remote or it wil...

Страница 15: ...can provide 2 watts of heat for every watt of electricity it consumes As outdoor temperatures drop the heating capacity and efficiency of the heat pump declines At temperatures below 45 F it is likely...

Страница 16: ...ns within 5 seconds You can select 30 minute intervals from 30 minutes to 24 hours 3 Press the TIMER button again to confirm the setting The TIMER light on the control panel will be activated At the e...

Страница 17: ...of the unit will be contaminated with dirt which may cause performance failure or damage to parts 4 Clean the air conditioner Use a soft dry cloth to wipe the air conditioner or use a vacuum cleaner t...

Страница 18: ...struction Provide additional support for unit Water hitting fan blade Normal in high humidity Stop noise by removing drain plug or adding condensate drain cup Unit oversized for application compressor...

Страница 19: ...remote control and the signal receiver on the unit Check the batteries in the remote UNIT BLOWS FUSES OR POPS CIRCUIT BREAKER Make sure there are enough available amps on the circuit for the air cond...

Страница 20: ...Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_2PAHP...

Отзывы: