background image

7

CABINET INSTALLATION

 STEP 1:

TOP RAIL

1.

  Remove the air conditioner and top rail (G) from the 

carton and place them on a flat surface.

2.

  Align the holes in the top rail with those in the top of 

the unit.

3.

  Secure the top rail to the unit with three of the 3/8 

inch short screws (D) as shown in the diagram below. 

NOTE:

 Higher side of the top rail is to be facing the 

inside of the room.

D–

G–

D–

D–

D.  #10 x 3/8

 

pan-head Phillips 

screws (3x)

G.  Top Rail

 STEP 2: 

ATTACH SIDE ACCORDION PANELS

1.

  Insert top and then bottom of right-hand accordion 

panel to top rail and bottom guide on air  

conditioner cabinet. 

Accordion
Panel

Top Rail

    

2.

  Extend the right-hand accordion panel outward so 

you can insert the first screw through the middle hole 

of the accordion panel. Using #10 x 1/4 inch pan-

head Phillips Screw (C), screw accordion panel to 

middle hole in air conditioner cabinet.

NOTE:  

These (6x)  Phillips screws (C) are  required to correctly 

 attach accordion panel  to the air conditioner  cabinet.

3.

  While the right-hand 

accordion is still 

extended, insert 

the #10 x 1/4 inch 

pan-head Phillips 

screws (C) into the 

top and bottom slots 

of accordion. Screw 

accordion to the top 

and bottom holes 

in air conditioner 

cabinet.

NOTE: 

Some accordion panels may have 2 slots at each 

end. You will be able to see a mounting hole through the 

correct slot.

4.

  Slide accordion panel housing into guides as far as it 

will go.

5.

  Repeat the above steps for the left-hand  

accordion panel.

 STEP 3: 

ATTACH FOAM 

ADHESIVE 

SEAL

Attach foam adhesive 

seal (A) along the 

bottom of th accordion 

panel’s bottom guide.

 STEP 4: 

INSTALL CABINET INTO WINDOW

•  Handle air conditioner gently.

•  Be sure your air conditioner cabinet does not fall out 

 of the opening during installation or removal.

•  The location where the power cord exits the air 

conditioner should be no more than 4 ft from a 

grounded 3 prong outlet.

•  Do not block the louvers on the front panel.

•  Do not block the louvers on the outside of the air 

conditioner. If air is obstructed and/or deflected back 

into the unit, the air conditioner’s compressor may 

cycle on and off rapidly. This could damage the unit. 

INNER SILL

OUTER SILL

FOR STORM WINDOWS

WOOD FOR

INNER SILL

STORM WINDOW

FRAME

WOOD

STRIP

CAUTION: 

Do not install this air conditioner in 

 

a window if the bolts do not make contact with the window sill.

BOTTOM VIEW

BACK VIEW

Accordion

Panel

Bottom Guide

Accordion

Panel

Bottom Guide

Содержание 2PAHP12002

Страница 1: ...WINDOW AIR CONDITIONER FOR MODEL 2PAHP12002 WITH HEAT PUMP Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Страница 3: ...aintenance of this unit Contact an installer for installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be...

Страница 4: ...om the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so...

Страница 5: ...d of time un plug or turn OFF main power switch Leaving power on may cause unit failure or fire DO NOT place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure o...

Страница 6: ...tioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling th...

Страница 7: ...ging Airflow Direction Airflow on unit may be diverted left or right from center by louvers Upward and downward air discharge is provided by tilting louvers Adjust tilt louvers for desired airflow dir...

Страница 8: ...must be outdoors not inside a building or garage Inner sill Offset Window Sill Exterior Interior wall 27 39 16 min Sash Check the location where the unit will be installed Proper installation is your...

Страница 9: ...packing foam from inside of unit Handle NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material WARNING DO NOT operate unit with...

Страница 10: ...and bottom slots of accordion Screw accordion to the top and bottom holes in air conditioner cabinet NOTE Some accordion panels may have 2 slots at each end You will be able to see a mounting hole thr...

Страница 11: ...URING ACCORDION TO THE WINDOW FRAME 1 Pull left hand accordion panel out until it reaches the window frame Use a 3 32 drill bit to drill a starter hole through the hole in the accordion panel housing...

Страница 12: ...out Condensate Drain Cup 1 2 Diameter Hose Outer Case 1 Insert air conditioner into cabinet 2 Install shipping screws on both sides of cabinet 3 Plug the control panel to the unit 4 Insert front tabs...

Страница 13: ...crements up to 24 hours The TIMER ON OFF indicator will be on when the timer has been set TIMER OFF Turn the unit on to set the desired temp and fan speed Press the TIMER button Press the TEMP TIMER b...

Страница 14: ...DO NOT place the remote where it is exposed to direct sunlight or strong lights DO NOT drop anything on the remote as this may cause damage DO NOT block the area between the unit and remote or it wil...

Страница 15: ...can provide 2 watts of heat for every watt of electricity it consumes As outdoor temperatures drop the heating capacity and efficiency of the heat pump declines At temperatures below 45 F it is likely...

Страница 16: ...ns within 5 seconds You can select 30 minute intervals from 30 minutes to 24 hours 3 Press the TIMER button again to confirm the setting The TIMER light on the control panel will be activated At the e...

Страница 17: ...of the unit will be contaminated with dirt which may cause performance failure or damage to parts 4 Clean the air conditioner Use a soft dry cloth to wipe the air conditioner or use a vacuum cleaner t...

Страница 18: ...struction Provide additional support for unit Water hitting fan blade Normal in high humidity Stop noise by removing drain plug or adding condensate drain cup Unit oversized for application compressor...

Страница 19: ...remote control and the signal receiver on the unit Check the batteries in the remote UNIT BLOWS FUSES OR POPS CIRCUIT BREAKER Make sure there are enough available amps on the circuit for the air cond...

Страница 20: ...Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_2PAHP...