background image

6

6

Cautions

Cautions

- This appliance can be used by children aged from 8 years and above and person with reduced physical,

sensory or mental capabilities or lack of experience and knowledge if they have been given supervision

or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children

shall not play with the appliance. Cleaning and user maintenance shall not be made by children without

supervision.  (be applicable for the European Countries)

- This appliance is not intended for use by persons (including child

re

n) with reduced physical, sensory or

mental

 

capabilities or lack of experience and knowledge, unless they have been given supervision or

instruction

 

concerning use of the appliance by a person responsible for their safety.  Children should be

supervised to

 

ensure that they do not play with the appliance.(be applicable for other countries except the

European

 

Countries )

- If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or similarly qualified

persons in order to avoid a hazard.

- Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.

- Do not install the appliance in a location that may be exposed to combustible gas. If combustible gas

7

- If the appliance is knocked over during use, turn off the unit and unplug it from the main power supply

immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been

damaged,

 

contact a technician or customer service for assistance.

- In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.

- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route

cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

- Do not operate unit with a damaged cord or plug. Discard unit or return to an authorized service facility for

examination and/or repair.

- To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

- The appliance shall be installed in accordance with national wiring regulations.

- Contact the authorised service technician for repair or maintenance of this unit.

- Turn off the product when not in use.

 accumulates around the unit, it may cause fire.

8

Operation

Place correctly

-This unit is designed to operate with a working

environment between 5°C(41°F) and 32°C(90°F).

more than 40cm

more than 20cm

more than 20cm

more than 40cm

more than 20cm

Casters(Installed at four points on the bottom of unit)

-Do not force casters to move over carpet, nor

move the unit with water in the bucket.

(The unit may tip over and spill water.)

NOTE: Casters is optional, some models without.

Smart functions:
-Auto Shut Off

When the bucket full indicator light illiminates or the

setting humidity is reached, the unit will be shut off 

automatically.

-Wait 3 minutes before resuming operation

After the unit has stopped,  it can not be restart

opertation in the first 3 minutes. This is to protect the

unit. Operation will automatically start after 3 minutes.

-Auto Defrost

When frost builds up on the evaporator coils, the

compressor will cycle off and the fan will continue to

run until the frost  disappears.

-Auto-Restart

If the unit breaks off unexpectedly due to the power

cut, it will restart with the previous function setting

automatically when the power resumes.

Operation

9

PUMP button(optional)

Press to activate the pump operation.

NOTE: Make sure the pump drain hose is installed into the 

unit and the continuous drain hose is removed from the unit 

before the pump operation is activated. When the bucket is full,

the pump starts to work. Refer to the next pages for removing 

the collected water. Do not use this operation when the outdoor 

temperature is equel to or less than 0ºC (32ºF).

COMFORT button

Press to activate the comfort dehumidifying operation.

NOTE: On this operation,the unit can not be set humidity level. 

FILTER button

The check filter feature is a reminder to clean the Air Filter for 

more efficient operation. The Filter light(Clean filter light) will 

flash after 250 hours of operation. To reset after cleaning 

the filter, press the Filter button and the light will go off. 

Press the filter pad for 3 seconds when the unit is on or off to 

CONTINUE button

Press to activate the continuous dehumidifying operation.

NOTE: The control panel of the unit you purchased may be look like one of the followings:

On

Off

Full

Auto defrost

On

Off

Full

Defrost

TURBO button

Control the fan speed. Press to select either High or Normal fan 

speed. Set the fan control to High for maximum moisture removal. 

When the humidity has been reduced and quiet operation is 

preferred, set the fan control to Normal.

Press to initiate the Auto start and Auto stop feature, in conjuction 

Timer button

initiate the Wireless connection mode.The LED DISPLAY shows  

AP  to indicate you can set Wireless connection and the 

compressor is forced off. If connection (router) is successful within 

8 minutes, the unit will exit Wireless connection mode automatically 

and the Wireless light(Filter light) illuminates and the compressor 

reverts previous state. If connection is failure within 8 minutes, the 

unit exits the Wireless connection mode automatically.

Содержание 1PFD22

Страница 1: ...DEHUMIDIFIER FOR MODELS 1PFD22 1PFD35 1PFD50 Before using your dehumidifier please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Страница 2: ......

Страница 3: ...1 Contents P reparation S afety P recautions Cautions O peration Maintenance Faults Diagnosis S ociable Remark 4 5 6 9 9 10 7...

Страница 4: ...f this unit must be performed by a certified technician Product uninstallation and recycling must be performed by a certified technician Note About Fluorinated Gasses NOTE All the illustrations in the...

Страница 5: ...tructions must be followed Incorrect operation due to ignoring of instructions may cause death harm or damage This symbol indicates that ignoring instructions may cause death or serious injury Safety...

Страница 6: ...Prior to cleaning or other maintenance the appliance must be disconnected from the supply mains Do not install the appliance in a location that may be exposed to combustible gas If combustible gas 7...

Страница 7: ...he next pages for removing the collected water Do not use this operation when the outdoor temperature is equel to or less than 0 C 32 F COMFORT button Press to activate the comfort dehumidifying opera...

Страница 8: ...vailable for the unit with pump feature with the and buttons When the unit is on first press the Timer button the Timer Off indicator light illuminates It indicates the Auto Stop program is initiated...

Страница 9: ...ff the unit wait one day before emptying the bucket Clean the main unit bucket and air filter Wrap the cord and bundle it with the band Cover the unit with a plastic bag Store the unit upright in a dr...

Страница 10: ...A The municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old prod...

Страница 11: ......

Страница 12: ...1 Dansher Rd Countryside IL 60525 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_1PFD22_1PF...

Отзывы: