Familiarise yourself with the functions of the device before actually using it.
All modifications of the device are forbidden for safety reasons. Damage caused by user modifications
to the device is not covered by the warranty.
Only use the device for its intended purpose. All other uses may lead to short circuits, burns,
electroshocks, lamp explosion, crash, etc. Using the device in an unauthorised way will void the
warranty.
Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and
the dealer will not accept responsibility for any ensuing defects or problems.
Use the original packaging if the device is to be transported.
Keep this manual for future reference.
4.
Features
floodlight for commercial or residential use
slim design
adjustable bracket
integrated microwave sensor
o
settings: sensitivity (4 levels)
o
delay time adjustment (12 presets)
o
mode changing (day, night, photocell, continuous, flash and SOS mode)
suited for outdoor use: IP65
5.
Installation
5.1
Guidelines
The construction to which the device is attached should be able to support 4 times the weight of the
device for one hour without deformation.
Never stand directly below the device when it is being mounted, removed or serviced. Have a
qualified technician check the device once a year and once before you bring it into service.
Overhead mounting requires extensive experience: calculating workload limits, determining the
installation material to be used… Have the material and the device itself checked regularly. Do not
attempt to install the device yourself if you lack these qualifications as improper installation may
result in serious injuries.
This device is not suitable for dimming.
5.2
Distances
Keep at least 20 cm distance at the top and 30 cm on either side.
Respect a minimum distance of 1 m between the device’s light output and any illuminated surface.
5.3
Choosing an appropriate location
You can adjust the detection area according to your needs: turn the device to the left or right and
aim it up or down. Note that the detector is much more sensitive to objects moving across the
detection area than it is to objects coming straight at it. This is a very important consideration when
selecting the mounting location.
Please avoid installing the floodlight upside-down in order to ensure its watertightness.
The floodlight should be fixed to a stable outdoor wall made of a non-flammable material
approximately between 0.5-3.0 m above the ground and at an angle of ± 60°, preferably in a
location under eaves where the unit is protected from the elements and shielded from direct sunlight.
Do not block the front of the detection window and make sure the detection area holds no moving
objects.
Do not install the device close to air conditioning vents, radiators, etc.