
EVM1400_v2
PEREL
7
•
Temperature Measurement
1.
Set the rotary selector at the desired °C range.
2.
The LCD will display the current ambient temperature.
3.
Connect the black test lead of the “K” type thermocouple to the COM jack and the red test lead to the
°C jack.
4.
Touch the object to be measured with the thermocouple.
•
Humidity Measurement
1.
Set the rotary selector at the desired %RH range.
2.
The LCD will display the current ambient humidity.
Note:
•
The meter will need a few seconds to stabilize the humidity reading.
•
Sound Level Measurement
1.
Set the rotary selector at the desired dB range.
2.
The LCD will display the current ambient sound level.
•
Illuminance Measurement
1.
Set the rotary selector at the desired Lux range.
2.
Move the meter in front of the light source to be measured.
3.
The LCD will display the current illuminance level.
5. Cleaning and Maintenance
Do not attempt to repair or service your multimeter unless you are qualified to do so and have the relevant
calibration, performance test and service information.
a.
General Maintenance
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
Clean the terminals:
•
Turn the meter off and remove all test leads.
•
Shake out any dirt that may be in the terminals.
•
Soak a new cotton bud with a cleaning and oiling agent and clean the terminal.
To avoid electrical shock and/or damage to the instrument, do not connect the thermocouple
to a live circuit.
To avoid electrical shock and/or damage to the instrument, do not connect the input to a live
circuit.
To avoid electrical shock and/or damage to the instrument, do not connect the input to a live
circuit.
To avoid electrical shock and/or damage to the instrument, do not connect the input to a live
circuit.
To avoid electrical shock and/or damage to the instrument, do not get water inside the case.
Remove the test leads and any input signals before opening the case.
Содержание EVM1400
Страница 2: ......