PERCo TTD-03.2 Скачать руководство пользователя страница 21

Operation manual 

20 

Table 3.  Potential control mode (the jumper is taken off from the connector J1) 

 

The 

turnstile 

operating 

modes  

Actions to do  

Indication 

on the

 

RC-

panel  

Indication on the 

turnstile housing 

display  

Response to the barrier 

arm turning  

Both 

directions 

are closed  

The high level is 

on contacts 

Unlock A and 

Unlock B or low 

level on the 

contact Stop 

The red 

indicator 

above the 

STOP 

button is on  

The two “Red 

cross” pictograms 

(left and right) are 

on  

 

One of the 

passage 

directions 

is open 

The low level is 

on the contact 

corresponding to 

the passage 

direction, the 

high level is 

present on the 

other contacts 

The green 

indicator 

above the 

button of the 

chosen 

passage 

direction is 

on  

The “Green arrow” 

pictogram, showing 

the passage 

direction, and the 

“Red cross” 

pictogram from the 

opposite side are 

on  

If by the moment of 

passing through the 

turnstile the low level is 

present on the contact 

corresponding to the set 

passage direction, the 

turnstile remains open in 

the set direction 

Both 

passage 

directions 

are open  

The low level is 

on the contacts 

corresponding to 

the both 

directions, the 

high level is on 

the contact Stop 

The two 

green 

indicators 

(left and 

right) are on 

The two “Green 

arrow” pictograms 

(left and right) are 

on 

If by the moment of 

passing through the 

turnstile the low level is 

present on the contact 

corresponding to the set 

passage direction, the 

turnstile remains open in 

the set direction 

 

 

For the ACS outputs note the following: 

High level — contacts of the output relay are broken or the output transistor is closed. 

Low level — contacts of the output relay are closed or the output transistor is open. 

9.4  Actions in emergency 

For urgent evacuation of people from business facilities in case of fire, natural calamities or other 

emergencies, the additional emergency exit should be provided. The anti-panic barrier section of 

rotary type can be used as an emergency exit. 
The additional emergency exit can be provided by the turnstiles equipped with anti - panic drop 

arms. The anti -  panic drop arms allow to set the passageway free without any special keys or 

tools. To drop the anti - panic arm down just pull out the arm towards its axis direction, until the 

rotation mechanism becomes free, and then turn the arm down (see Fig. 12). 

 

Fig. 13.  Anti-panic drop arms application 

When using the standard barrier arms, it is possible to provide free passage through the turnstile 

by unblocking it with the mechanical release key.  

Содержание TTD-03.2

Страница 1: ...OPERATION MANUAL TTD 03 2 Electromechanical Box Tripod Turnstile...

Страница 2: ...Electromechanical Box Tripod Turnstile TTD 03 2 Operation Manual...

Страница 3: ...to the turnstile 11 5 5 Operation contingencies and response 13 6 Marking and packaging 13 7 Safety requirements 13 7 1 Installation safety requirements 13 7 2 Operation safety requirements 13 8 Inst...

Страница 4: ...for information on the throughput of the turnstile 2 OPERATION CONDITIONS The turnstile in accordance with the resistance to environmental exposure is compliant with GOST15150 69 category NF4 operati...

Страница 5: ...dimensions 5 PRODUCT DESCRIPTION 5 1 Main features The turnstile can be operated both autonomously with the RC panel or WRC and with an ACS The turnstile housing is supplied with the safe voltage not...

Страница 6: ...mechanism consisting of a damper rotation sensor disk and a hub 16 with three barrier arms 6 The interior components of the housing can be accessed through the removable top cover 1 During operation t...

Страница 7: ...indication module 6 barrier arm 7 mechanical release lock 8 mechanical release key 9 turnstile housing cover lock 10 turnstile housing cover key 11 turnstile power supply 12 RC panel WRC kit ACS contr...

Страница 8: ...electrical connection layout see Fig 13 On control board there is a microcontroller which processes incoming control commands inputs Unlock A Stop Unlock B and Fire Alarm traces the condition of barri...

Страница 9: ...ement there can be used a normally open relay contact or a circuit with open collector output at that At the emergency unblocking device input the turnstile control is carried out by elimination of a...

Страница 10: ...turnstile There can be two control modes of the turnstile pulse and potential Those control modes determine available operating modes of the turnstile see Tables 3 and 4 The control mode variant is se...

Страница 11: ...ns open in the set direction At the low level signal inputting to the Stop input both directions are closed for the time of the signal duration regardless the signal strength at the inputs Unlock A an...

Страница 12: ...icrocontroller removes the signal PASS A B the PASS A B and Common contacting The Always free operating mode particularity in this mode the command described in point 5 is not generated and the set pa...

Страница 13: ...oth passage directions become open for the whole period of the signal absence Other controlling commands are ignored at that When the low level signal appears at the Fire Alarm input the turnstile tur...

Страница 14: ...ile housing cover 1 by unlocking the turnstile housing cover lock 9 with the key 10 and turning it clockwise up to the stop the lock cylinder moves out of the case Shift the cover to the right up to t...

Страница 15: ...turning at the angle of more than 60 the reset to home position is effected in the direction of movement at the barrier arm turning at the angle less than 60 the reset to home position is effected in...

Страница 16: ...he turnstile housing base 4 remove the turnstile housing cover 1 and both outer panels 2 Thus you get an access to the mounting holes of the turnstile housing base 4 Fix the turnstile housing after la...

Страница 17: ...16 unscrewing the screw 18 Unscrew the fixing bolt 19 on the barrier arm 6 Fit the barrier arm into the mounting hole on the hub 16 and fasten it with the bolt 19 Put a spring washer under the bolt h...

Страница 18: ...the test indicator inside the intrusion detector going off from 10 to 50 sec the turnstile should be in the Always locked mode at the pulse control mode or in the Both directions closed at the potent...

Страница 19: ...accuracy of all the connections and of the power supply cable operability see Clause 8 4 5 of this Manual 2 Connect the AC power cable 15 of the turnstile power supply 11 to the AC outlet socket with...

Страница 20: ...the set direction 5 Free passage in the set direction and single passage in the opposite direction Carry out actions stated in Chapters 2 and 4 of the present table in any order The two green indicat...

Страница 21: ...n the contact Stop The two green indicators left and right are on The two Green arrow pictograms left and right are on If by the moment of passing through the turnstile the low level is present on the...

Страница 22: ...housing cover and remove the outer panel Check the RC panel WRC kit ACS controller cable serviceability and reliability of its connection to the CLB XT1 L and XT1 H connector blocks Other possible fau...

Страница 23: ...the S17 socket wrench At the end of the maintenance works 1 mount the outer panels 2 of the turnstile back into their places 2 mount the turnstile housing cover 1 in the reverse order as described ab...

Страница 24: ...the contact Unlock B or active front is at the contact Stop while there is a low level at the contact Unlock A and a high level at the contact Unlock B At this command the passage direction A opens u...

Страница 25: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Страница 26: ...www perco com...