![PERCo TTD-03.2 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/perco/ttd-03-2/ttd-03-2_operation-manual_1528208021.webp)
Operation manual
20
Table 3. Potential control mode (the jumper is taken off from the connector J1)
№
The
turnstile
operating
modes
Actions to do
Indication
on the
RC-
panel
Indication on the
turnstile housing
display
Response to the barrier
arm turning
1
Both
directions
are closed
The high level is
on contacts
Unlock A and
Unlock B or low
level on the
contact Stop
The red
indicator
above the
STOP
button is on
The two “Red
cross” pictograms
(left and right) are
on
2
One of the
passage
directions
is open
The low level is
on the contact
corresponding to
the passage
direction, the
high level is
present on the
other contacts
The green
indicator
above the
button of the
chosen
passage
direction is
on
The “Green arrow”
pictogram, showing
the passage
direction, and the
“Red cross”
pictogram from the
opposite side are
on
If by the moment of
passing through the
turnstile the low level is
present on the contact
corresponding to the set
passage direction, the
turnstile remains open in
the set direction
3
Both
passage
directions
are open
The low level is
on the contacts
corresponding to
the both
directions, the
high level is on
the contact Stop
The two
green
indicators
(left and
right) are on
The two “Green
arrow” pictograms
(left and right) are
on
If by the moment of
passing through the
turnstile the low level is
present on the contact
corresponding to the set
passage direction, the
turnstile remains open in
the set direction
For the ACS outputs note the following:
High level — contacts of the output relay are broken or the output transistor is closed.
Low level — contacts of the output relay are closed or the output transistor is open.
9.4 Actions in emergency
For urgent evacuation of people from business facilities in case of fire, natural calamities or other
emergencies, the additional emergency exit should be provided. The anti-panic barrier section of
rotary type can be used as an emergency exit.
The additional emergency exit can be provided by the turnstiles equipped with anti - panic drop
arms. The anti - panic drop arms allow to set the passageway free without any special keys or
tools. To drop the anti - panic arm down just pull out the arm towards its axis direction, until the
rotation mechanism becomes free, and then turn the arm down (see Fig. 12).
Fig. 13. Anti-panic drop arms application
When using the standard barrier arms, it is possible to provide free passage through the turnstile
by unblocking it with the mechanical release key.