RTD-03S Waist-high rotor turnstile
19
№
Turnstile operating
mode
Your actions
Indication on
the RC
Indication
outputs
status
Turnstile status
6
Always free (open for
entry and exit)
Press all the three
buttons on the RC
simultaneously
The two green
indicators (left
and right) are on
“LED Grn_L”
and
“LED Grn_R”
outputs are
active
The barrier wings
rotation in any
direction is allowed
without any
limitations
9.3 Operation from the built-in SPS
In case of the AC mains failure the turnstile remains operative and turns to the built-in SPS (the
“Battery”
toggle switch is in the
“I”
position). When operating from the SPS the
“Battery”
indicator on the CU is on and the
“Power”
indicator is off. The
“Pwr failure”
signal, notifying of
the AC mains failure, is transmitted to the CU
“ACS”
connector. In about 5 seconds there will be
intermittent indication (with blinking interval of 1 second) on the RC.
At the SPS battery discharge up to 22±0,5V, in addition to the intermittent indication, an audio
signal with 30 seconds interval, warning about the discharge, will be generated by the RC. This
signal, consisting of six short signals, is generated only in the
“Always locked”
mode every 30
seconds. The
“Bat failure”
signal will be formed at the CU
“ACS”
connector.
At the SPS battery discharge up to 20.8±0.5V the gate will turn to the
“Always locked”
mode. The
passage modes setting by the RC or ACS is blocked. The indicator above the
“STOP”
button will
start blinking with interval of 2 seconds. At the further battery discharge the CU will automatically
switch off.
When the AC mains is restored, the turnstile turns to the AC mains (the
“Power”
toggle switch is
in the
“I”
position). The built-in SPS battery will recharge automatically, if the
«Battery»
toggle
switch is in the
“I”
position.
Operation time with the built-in SPS is 1.5 hours or 1,200 passages provided that the battery is
fully charged.
Note!
The
CU SPS contains a lead-acid battery, which is not recommended to be stored for a long
time without recharge. For recharge during the storage period the CU must be switched on
for 24 hours every 8 months (every 2 months when storing at ambient temperature above
+30
°
C).
The sequence of actions is given in Clause 9.1. It is allowed not to connect the gate post or the RC
to the CU during discharge.
9.4 Operation from the external power supply
The external power supply is connected via the
“Bat=24V”
connector, located on the CU lower
panel. Pin assignments for external power supply connector are shown in Fig. 4.
The external power supply connector (XLR3 cable plug) is included in the set of spare parts.
To connect the external power supply:
•
Turn the toggle switches “
Power
” and “
Battery
” to the “
O
” position;
•
Remove the “
Bat/2A
” fuse on the CU lower panel;
•
Connect the external power supply and turn the “
Battery
” toggle switch to the “
I
” position.
Operation from the external power supply is similar to the operation with the built-in SPS as given
in Clause 9.3 of the Manual.
9.5 Troubleshooting
Possible faults, which can be cleared by the users themselves, are listed in Table 3.