Operation manual 

16 

Table 1. List of elements of the turnstile connection layout 

Legend 

Item 

Qty. 

Comments 

A1 

Turnstile post  

 

A2 

Control unit  

 

A3 

Processor module 

 

A4 

Remote control panel  

 

A5

  Wireless remote control 

 

A6

  ACS controller 

 

A7

  External power supply  

24VDC 

A8

  Intrusion detector  

 

A9

  Siren 

 

A10

  Railing set with indication modules 

 

Power cable 

 

Control cable 

 

Indicator cable 

 

* – optional 

9  OPERATION INSTRUCTIONS 

 

Warning! 

It is prohibited:

 

 To use abrasive or chemically active substances for cleaning the external surfaces; 

 To move through the gate passage area any objects with dimensions exceeding the width 

of the passageway; 

 To jerk or hit the swing panel and the gate post so as to prevent their mechanical 

deformation.

 

9.1  Power-up 

 

Warning! 

Observe general electrical safety requirements during the turnstile operation. 

  Check the accuracy of all the connections and the AC power cable operability; 

  Prior to the turnstile power-up, set the 

«Power»

 toggle switch and the 

«Battery»

 toggle switch 

to the 

“O”

 position; 

  Install the 

«Bat/2A»

 fuse, which is provided together with the set of spare parts, into the fuse 

slot on the CU lower panel; 

  Connect the AC power cable (12) of the CU (8) to the 220V / 50Hz AC outlet; 

  Check the rotation in either direction is blocked with the mechanical release key; 

  Clear the passage area; 

 

Warning! 

Do not connect the control unit to the mains with the voltage and frequency rating other than 

specified in Chapter 3 of this Manual. 

  Set the «Power» toggle switch and the «Battery» toggle switch to the “I” position. At the same 

time the indicators «Power» and «24V» on the CU (8) will light up, a two-tone audio signal will 

be generated. The indicator above the STOP button on the RC (9) will light up. 

See instructions below: 

  Any operating mode is set by pushing the buttons of the RC or the tag of the wireless remote 

control kit. 

  After pushing the STOP button the turnstile is set in the “Always locked” mode, and the barrier 

wings return to the reset state.  

Содержание RTD-03S

Страница 1: ...OPERATION MANUAL RTD 03S Waist high Rotor Turnstile...

Страница 2: ...Waist high Rotor Turnstile RTD 03S Operation manual...

Страница 3: ...anical unblocking of the turnstile 11 6 MARKING AND PACKAGING 12 7 SAFETY REQUIREMENTS 12 7 1 Installation safety requirements 12 7 2 Operation safety requirements 12 8 INSTALLATION INSTRUCTIONS 12 8...

Страница 4: ...egory U4 operation in premises with climate control Operation of the turnstile post is allowed at ambient temperature between 1 C and 45 C and relative air humidity up to 98 at 35 C The control unit i...

Страница 5: ...ppendix 1 Wireless remote control kit 1 Note Wireless remote control kit consists of a receiver and 2 transmitters tags with operation range up to 40 m 5 BRIEF DESCRIPTION 5 1 Main features The turnst...

Страница 6: ...1 Four barrier wings 6 are mounted on the rotary post 1 The filler panels 7 are set into the barrier wings 6 with the fastenings 15 On the rotary post 1 cover 3 there is the mechanical release lock 4...

Страница 7: ...panel which are intended for setting the turnstile operating modes The LED indicators are located above the buttons The button in the middle hereinafter the STOP button is intended to set the turnstil...

Страница 8: ...RTD 03S Waist high rotor turnstile 7 Figure 3 Control unit...

Страница 9: ...cable connector Control Power cable connector DC 24V External DC power supply connector Bat 24V AC power cable input 220V Entry for intrusion detector and siren cables Alarm Connections for intrusion...

Страница 10: ...he X5 connector of the processor module see Fig 9 If the jumper is fixed pulse control the jumper is not fixed potential control The control unit is supplied with pulse control mode preset the jumper...

Страница 11: ...Pass Sensor Pwr failure and Bat failure have the galvanic decoupling a Control elements of an external device a normally open relay contact b Control elements of an external device a circuit with ope...

Страница 12: ...locking of the turnstile Possibility to unblock the turnstile manually is specially provided for unblocking the turnstile in the emergency mode at all the power supplies failure AC mains switching off...

Страница 13: ...l safety requirements for use of electrical equipment Don ts Do not use the turnstile under conditions that do not comply with the requirements of Chapter 2 of this Manual Do not mount the control uni...

Страница 14: ...raceways for the control cable 10 and the power cable 11 as shown in Fig 7 and according to your checkpoint layout Figure 7 Marking layout for RTD 03S installation dotted line shows the dimensions of...

Страница 15: ...ttings 14 holes Check the strong fastening of the barrier wings 6 and the filler panels 7 8 Check free rotation of the rotary post 1 Unblock the rotary post with the mechanical release key 5 see Claus...

Страница 16: ...ector put remote control cable 13 through its cable inlet inside the control unit and connect it to the X3 and X4 connectors on the processor module as per Fig 9 11 Set the CU Power toggle switch and...

Страница 17: ...s and the AC power cable operability Prior to the turnstile power up set the Power toggle switch and the Battery toggle switch to the O position Install the Bat 2A fuse which is provided together with...

Страница 18: ...nd for the new passage mode entered by the RC will be enquired in the command queue of the turnstile After the barrier wing is reset to the reset state the command from the command queue will be perfo...

Страница 19: ...Grn_L or LED Grn_R output is active depending on the set direction The barrier wings rotation in the set direction is allowed 3 Bidirectional single passage open for one by one person passage in each...

Страница 20: ...will start blinking with interval of 2 seconds At the further battery discharge the CU will automatically switch off When the AC mains is restored the turnstile turns to the AC mains the Power toggle...

Страница 21: ...e and when the CU is powered up with the external SPS via the Bat 24V connector the Battery toggle switch is in the I position the Bat 2A fuse is not installed the turnstile does not work the indicato...

Страница 22: ...Guide barriers set posts polished tubular stainless steel dia 50 mm rails beechwood ashwood filler panels tinted polycarbonate plastic mnemonic indication units RB 03S guide barriers set Guide barrier...

Страница 23: ...r stainless steel dia 50 mm rails polished tubular stainless steel dia 32 mm filler panels tinted polycarbonate plastic symbol indication units RB 03T guide barriers set Guide barriers set posts polis...

Страница 24: ...ut for installation of turnstile with guide barriers set electric raceway to the control unit is laid from the turnstile post center in the direction of the control unit according to the layout Figure...

Страница 25: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Страница 26: ...www perco com...

Отзывы:

Похожие инструкции для RTD-03S