background image

RTD-03S Waist-high rotor turnstile 

Dear customer! 

We thank You for choosing the turnstile manufactured by PERCo.  

You have purchased the high quality product, which will be long lasting  

in operation provided that installation and operation rules are observed. 

The operation manual for RTD-03S waist-high rotor turnstile contains data that is necessary for the 

most full usage of operating advantages of the turnstile as well as chapters on packaging, 

installation and maintenance.  Only qualified personnel, following the instructions of this Manual, 

must carry out installation and maintenance. 
Abbreviations and terms used in this Manual: 

 

ACS – access control system; 

 

CU – control unit; 

 

RC – remote control panel; 

 

SPS – standby power supply. 

1  APPLICATION 

The turnstile is designed for managing pedestrian flows at entrance checkpoints of industrial 

facilities, banks, administrative buildings, retail outlets, railway terminals, airports, etc. 
To ensure fast and convenient passage it is recommended to install one turnstile per every 500 

people, working in the same shift, or on the basis of maximum working load 23 persons/min. 

2  OPERATION CONDITIONS 

The turnstile post, in accordance with the resistance to environmental exposure, is compliant with 

GOST 15150-69, category U4 (operation in premises with climate control). 
Operation of the turnstile post is allowed at ambient temperature b1°C and +45°C and 

relative air humidity up to 98% at +35°C. 
The control unit, in accordance with the resistance to environmental exposure, is compliant with 

GOST 15150-69, category NF4 (operation in premises with climate control). 
Operation of the control unit is allowed at ambient temperature b1°C  and +40°C  and 

relative air humidity up to 80% at +25°C. 

3  TECHNICAL SPECIFICATIONS 

AC operating voltage ............................................................................... 220 ± 22 V AC / 50 ± 1 Hz 

Power consumption ......................................................................................................... max. 60 W 

Turnstile post input DC voltage  ........................................................................................  max 36 V 

External power supply input DC voltage ..............................................................................  24÷27 V 

Throughput in the single passage mode ................................................................... 23 persons/min 

Throughput in the free passage mode ....................................................................... 30 persons/min 

Passageway width ............................................................................................................... 600 mm 

Operation time from the built-in SPS ................................................................................. min 1.5 hr 

Number of passages when operating from the built-in SPS ................................ min 1200 passages 

Rotor rotation force (at the center of the barrier wing) ..................................................... max 1.5 kgf 

Mean time to failure ...................................................................................... min 1000000 passages 

Mean lifetime .................................................................................................................. min 8 years 

Electric shock protection class: 

Turnstile post ......................................................................................................... III (IEC 61140) 

Control unit .............................................................................................................. I (IEC 61140) 

Ingress Protection Rating:  

Turnstile post ...................................................................................................... IP41 (EN 60529) 

Control unit ......................................................................................................... IP40 (EN 60529) 

Turnstile overall dimensions, see Fig. 1, (length × width × height) .................. 1202×1202×1007 mm 

Net weight of the turnstile post .......................................................................................... max 43 kg 

Control unit overall dimensions (length × width × height) ....................................... 295×290×76 mm 

Net weight of the control unit ...........................................................................................  max 8.7 kg 

Содержание RTD-03S

Страница 1: ...OPERATION MANUAL RTD 03S Waist high Rotor Turnstile...

Страница 2: ...Waist high Rotor Turnstile RTD 03S Operation manual...

Страница 3: ...anical unblocking of the turnstile 11 6 MARKING AND PACKAGING 12 7 SAFETY REQUIREMENTS 12 7 1 Installation safety requirements 12 7 2 Operation safety requirements 12 8 INSTALLATION INSTRUCTIONS 12 8...

Страница 4: ...egory U4 operation in premises with climate control Operation of the turnstile post is allowed at ambient temperature between 1 C and 45 C and relative air humidity up to 98 at 35 C The control unit i...

Страница 5: ...ppendix 1 Wireless remote control kit 1 Note Wireless remote control kit consists of a receiver and 2 transmitters tags with operation range up to 40 m 5 BRIEF DESCRIPTION 5 1 Main features The turnst...

Страница 6: ...1 Four barrier wings 6 are mounted on the rotary post 1 The filler panels 7 are set into the barrier wings 6 with the fastenings 15 On the rotary post 1 cover 3 there is the mechanical release lock 4...

Страница 7: ...panel which are intended for setting the turnstile operating modes The LED indicators are located above the buttons The button in the middle hereinafter the STOP button is intended to set the turnstil...

Страница 8: ...RTD 03S Waist high rotor turnstile 7 Figure 3 Control unit...

Страница 9: ...cable connector Control Power cable connector DC 24V External DC power supply connector Bat 24V AC power cable input 220V Entry for intrusion detector and siren cables Alarm Connections for intrusion...

Страница 10: ...he X5 connector of the processor module see Fig 9 If the jumper is fixed pulse control the jumper is not fixed potential control The control unit is supplied with pulse control mode preset the jumper...

Страница 11: ...Pass Sensor Pwr failure and Bat failure have the galvanic decoupling a Control elements of an external device a normally open relay contact b Control elements of an external device a circuit with ope...

Страница 12: ...locking of the turnstile Possibility to unblock the turnstile manually is specially provided for unblocking the turnstile in the emergency mode at all the power supplies failure AC mains switching off...

Страница 13: ...l safety requirements for use of electrical equipment Don ts Do not use the turnstile under conditions that do not comply with the requirements of Chapter 2 of this Manual Do not mount the control uni...

Страница 14: ...raceways for the control cable 10 and the power cable 11 as shown in Fig 7 and according to your checkpoint layout Figure 7 Marking layout for RTD 03S installation dotted line shows the dimensions of...

Страница 15: ...ttings 14 holes Check the strong fastening of the barrier wings 6 and the filler panels 7 8 Check free rotation of the rotary post 1 Unblock the rotary post with the mechanical release key 5 see Claus...

Страница 16: ...ector put remote control cable 13 through its cable inlet inside the control unit and connect it to the X3 and X4 connectors on the processor module as per Fig 9 11 Set the CU Power toggle switch and...

Страница 17: ...s and the AC power cable operability Prior to the turnstile power up set the Power toggle switch and the Battery toggle switch to the O position Install the Bat 2A fuse which is provided together with...

Страница 18: ...nd for the new passage mode entered by the RC will be enquired in the command queue of the turnstile After the barrier wing is reset to the reset state the command from the command queue will be perfo...

Страница 19: ...Grn_L or LED Grn_R output is active depending on the set direction The barrier wings rotation in the set direction is allowed 3 Bidirectional single passage open for one by one person passage in each...

Страница 20: ...will start blinking with interval of 2 seconds At the further battery discharge the CU will automatically switch off When the AC mains is restored the turnstile turns to the AC mains the Power toggle...

Страница 21: ...e and when the CU is powered up with the external SPS via the Bat 24V connector the Battery toggle switch is in the I position the Bat 2A fuse is not installed the turnstile does not work the indicato...

Страница 22: ...Guide barriers set posts polished tubular stainless steel dia 50 mm rails beechwood ashwood filler panels tinted polycarbonate plastic mnemonic indication units RB 03S guide barriers set Guide barrier...

Страница 23: ...r stainless steel dia 50 mm rails polished tubular stainless steel dia 32 mm filler panels tinted polycarbonate plastic symbol indication units RB 03T guide barriers set Guide barriers set posts polis...

Страница 24: ...ut for installation of turnstile with guide barriers set electric raceway to the control unit is laid from the turnstile post center in the direction of the control unit according to the layout Figure...

Страница 25: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Страница 26: ...www perco com...

Отзывы:

Похожие инструкции для RTD-03S