background image

CERTIFICATE  AND  OPERATION

MANUAL

RP-15.2

Proximity
Card  Reader

Содержание RP-15.2

Страница 1: ...CERTIFICATE AND OPERATION MANUAL RP 15 2 Proximity Card Reader...

Страница 2: ...Proximity Card Reader RP 15 2 Certificate and Operation Manual RU C RU 02 00073 4372 015 88226999 2013...

Страница 3: ...e reader under Wiegand interface 6 5 CONFIGURATION 8 5 1 Indication setting 8 5 2 Changing the format of the output data 8 6 SAFETY REQUIREMENTS 9 7 INSTALLATION PROCEDURE 9 7 1 Features of installati...

Страница 4: ...otects it from being damaged during transportation and storage The reader in the original package should be transported in closed freight containers or other closed type cargo transport units Storage...

Страница 5: ...3 cm Controller connection interface Wiegand Output and operation signal voltage Logic 1 min 4 3 V Logic 0 max 0 4 V Distance between the reader and external controller max 150 m Connection cable sta...

Страница 6: ...10302 H10304 and the production of EM Microelectronic Marin SA Each identifier has its own single code number of combinations more than 500 mlrd which is one time set at the stage of manufacture and c...

Страница 7: ...possible not earlier than 200 ms after identifier leaves stable reception zone Two wires are used for transmission data 0 and data 1 Occurrence of logic level 0 on one of the wires signals the presen...

Страница 8: ...in Figure 1 Control bit corresponds with the even parity for the next 12 bit data 2 Byte code 3 High order byte of card number 4 Low order byte of card number 5 Control bit corresponds with the odd pa...

Страница 9: ...nit Table 1 Indication setting Control signals at a connection cable of a reader LED light in different modes at external control blue wire yellow wire single line double line 0 0 green orange 0 HZ gr...

Страница 10: ...is made only upon power supply off Cable laying should be produced subject to electrical devices operation rules In case of faulty power supply reader operation is prohibited 7 INSTALLATION PROCEDURE...

Страница 11: ...d level Measuring tape 2m 7 3 The cables used Recommended cable type for connection reader to external controller RAMCRO SA82BI T CABS8 EC 8C SEC SC W8ekw cross section 24AWG 18AWG it is prohibited to...

Страница 12: ...to metal base plate Take off the metal base plate and fasten it with 4 screws from delivery set 5 If necessary to change the LED indication operation mode into double line two line control please cut...

Страница 13: ...e Customer and their remedy are given in the table below Table 3 Troubleshooting guide Fault Possible cause Remedy At the power up the LED indicator of the reader does not light reader does not react...

Страница 14: ...ce majeure circumstances natural disasters vandalism etc or defects as a result of external circumstances power surges electric discharge etc fuses accumulators galvanic elements and other components...

Страница 15: ...his Product will fit for the purposes not stipulated in the Product s in line documentation The warranty does not provide for any claims with regard to the technical specifications of the Product in c...

Страница 16: ...e of sale ____________________ 20___ ____________________________________ signature seal Cutting line Warranty Repair Coupon RP 15 2 Proximity card reader Serial number 5 3 7 Date of manufacture _____...

Страница 17: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Страница 18: ...www perco com...