CT/L-14 Controller
33
After card capturing, the card capture reader passes the “
Card captured”
signal, which the
controller uses as the confirmation of passage permission in the required direction through the OD.
One of additional controller inputs should be configured in software that when it is activated by the
“
Card captured
” signal, the controller opens the operating device in the required direction.
The card capture reader can generate “Alarm” signal (
Alarm
output) regarding to trouble in its
operation, signal of filling container) that can be applied to the free inputs of the controller by
configuring them to required responses (activation of appropriate sirens, etc.).
The settings of the card capture reader inputs and outputs should correspond to the settings of the
controller inputs and outputs (Sect. 5.4, 5.5).
When two turnstiles are connected to the controller, it is possible to control two card capture
readers - one for each turnstile. An example of such a connection is presented in Fig. 16.
IN5
input
must be configured as a confirmation input from EVD for resource #1, and
IN6
input as a
confirmation input from EVD for resource #2. In this example, the Alarm outputs of both card
capture readers are interconnected and connected to one common “Alarm” siren (12V / 0.2A). The
input signals indicating the passage direction of the
IC-05
card capture readers receive control
signals directly from the turnstile control boards.
Appendix 2. Instruction on connection of the
CT/L-14
through
PoE
-splitter
Attention!
•
Provided instruction refers to the splitters included in optional equipment delivery set.
•
Total power consumption of the controller and of all the devices powered by it must not
exceed 12 W. It is also recommended to leave min 10% reserve power.
Splitter description
PoE-splitter
(hereinafter –
splitter
) is designed for energizing equipment, connected via
Ethernet
network. Splitter operates with any network commutators (hereinafter –
Switch)
, supporting
technology of electric power transmission via
PoE
twisted pair wire and compatible with
IEEE
802.3af
standard.
Splitter is designed as a block of electronics in a plastic housing featuring the following outputs:
Con 1
– output for
Ethernet
cable from
Switch
connection
;
Con 2
– output for
Ethernet
controller cable connection;
Con 3
– power output for controller power cable connection.
Note:
For some models of splitters output voltage is chosen with a switch. Operating
PERCo
equipment it is necessary to place the switch in
“12V”
mode.
Requirements for connecting devices
The characteristics of power consumption of the controller when connected through splitter should
meet the following requirements:
Admissible value of supply voltage ............................................................................... 12±1.2 V
Minimum total current ............................................................................................. min. 120 mA
Maximum total current consumption (12V) .................................................................... max 1 A
Maximum total power consumption ............................................................................ max 12 W
In order to avoid exceeding the total power consumption, providing power from the controller to
connected optional equipment (siren, intrusion detector, etc.) and to controllers of the second level is
not recommended. Up to four readers and ODs can be connected to the controller powered from the
splitter. Up to four electromechanical locks or two turnstiles (see Table 7) can be connected as ODs.
Table 7. OD powered through
PoE
-splitter
Types of controller configurations
OD
“Controller to operate the locks”
Electromechanical lock (
LC, LB
and
LBP
– up to 4pcs).
“Controller to operate the turnstile”
Turnstile with power consumption no more than 9W
T-5, TTR-04.1, TTD-03.1, TTD-03.2