VISUNET GMP DM
Installation and Commissioning
21
9365
2006
-0
6
15
3
Installation and Commissioning
3.1
Preparation
Unpacking the unit
1. Check that all package contents are present and undamaged.
If anything is damaged, inform the shipper and contact the supplier.
2. Check that all items are present and correct based on your order and the shipping
documents.
If you have any questions, please contact Fuchs.
3. Keep the original packing material in case you need to store or ship the unit at a later
time.
3.2
Mounting in the field
VisuNet GMP is licensed for operation in confined spaces.
The cooling of VisuNet GMP does not require active components like CPU fan or water
cooling systems. For that reason there are no ventilation slots in the housing.
To avoid overheating during operation, follow the advices below for field installation:
•
Do not expose the VisuNet GMP to direct solar radiation or other heat sources.
•
As the heat will dissipate via the housing of the VisuNet GMP, provide sufficient air
circulation.
•
Keep the ambient temperature below the specified maximal value.
Mounting the VisuNet GMP
1. If you mount the VisuNet GMP on a pedestal, lead all connection cables from the buttom
up through the pedestal pipe (towards VESA adapter).
2. Lead the connection cables through the VESA adapter.
3. Attach the connection cables to the respective interface.
4. Screw the VisuNet GMP with 4 countersunk head screws (M5) on the VESA adapter at
the back of the housing.
Grounding the VisuNet GMP
Ground the VisuNet GMP via the VESA adapter grounding bolt with the back of the
housing. If you mount the VisuNet GMP on a pedestal, you will be able to use the
grounding bolt with the pedestal.
Note!
The VisuNet GMP is not delivered in sterile condition. Desinfect the device before using it
(spray/wipe disinfectant).