![Pepperl+Fuchs VAA-2E2A-KE1-S/E2 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/pepperl-fuchs/vaa-2e2a-ke1-s-e2/vaa-2e2a-ke1-s-e2_original-operating-instructions_1527688016.webp)
1
3
0
8
6
3
2
0
1
9
-0
4
16
VAA-2E2A-KE1-S/E2, VAA-2E2A-KE1P-S/E2
Technical Data
Input
Output
Programming Instructions
Directive Conformity
Number/type
2 safety-related inputs for mechanical contacts, monitored for
crossed circuits:
2 single-channel contacts: up to category 2/PL c in accordance
with ISO 13849-1 or
1 dual-channel contact: up to category 4/PL e in accordance with
ISO 13849-1
Cable length must not exceed 300 m per input.
Power supply
From AS-Interface
Voltage
20 VDC ... 30 VDC, pulsed
Current rating
Input current limited
≤
15 mA,
overload and short-circuit proof
Number/type
2 conventional electronic outputs, PNP
Power supply
From external auxiliary voltage U
AUX
Current
0.5 A per output
Voltage
≥
(U
AUX
- 0.5 V)
Profile
S-7.B
IO code
7
ID code
B
ID1 code
F
ID2 code
0
Data bit (function via AS-
Interface)
Input
Output
D0
Dyn. security code 1
OUT 1
D1
Dyn. security code 1
OUT 2
D2
Dyn. security code 2
-
D3
Dyn. security code 2
-
Parameter bit (programmable
via AS-Interface)
Function
P0
Output link:
P0 = 1 (default setting): The outputs are controlled via the AS-
Interface.
P0 = 0: The outputs are controlled via the AS-Interface or the
inputs. When the contact of an input is opened, the
corresponding output is activated.
P1
Not used
P2
Not used
P3
Not used
Electromagnetic compatibility
Directive 2014/30/EU
EN 62026-2:2013 EN 61496-1:2004