![Pepperl+Fuchs VAA-2E-KE1-S Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/pepperl-fuchs/vaa-2e-ke1-s/vaa-2e-ke1-s_original-instructions-manual_1527685015.webp)
Technical Data
1
8
2
3
1
4
2
0
2
0
-0
9
15
6
Technical Data
General specifications
Indicators/operating means
Electrical specifications
Input
Programming instructions
Slave type
Safety-Slave
UL File Number
E87056
LED FAULT
error display; LED red
red: communication error or address is 0
LED PWR
AS-Interface voltage; LED green
LED IN
switching state (input); 2 LED yellow
Rated operating voltage
26.5 ... 31.6 V PELV from AS-Interface
Rated operating current
70 mA
Protection class
III
Number/Type
2 safety-related inputs for mechanical contacts, cross-circuit
monitored: 2 single-channel contacts: up to category 2 / PL c in
accordance with EN ISO 13849-1 or 1, 2-channel contact: up to
category 4 / PL e in accordance with EN ISO 13849-1
Cable length must not exceed 300 m per input.
Supply
from AS-Interface
Voltage
20 ... 30 V DC pulsed
Current loading capacity
input current limited
15 mA,
overload and short-circuit resistant
Profile
S-0.B
IO code
0
ID code
B
ID1 code
F
ID2 code
0
99.6
48.5
50.5
22.5