Ultrasonic sensor
note below). All sensors must be parameterized for external synchronization by means of the sensor interface. See software description.
5. A high level (+U
B
) or a low level (-U
B
)on the synchronization input switches the sensor to standby mode if it is parameterized for external
synchronization.
Note:
Sensor response times will increase proportionally to the number of sensors that are in the synchronization string. This is a result of the
multiplexing of the ultrasonic transmit and receive signal and the resulting increase in the measurement cycle time.
Note:
The sensors syncronization input delivers an output current in case of low level and burdens with its input impedance in case of high level. Please
pay attention that the synchronizing device needs to have that driver capability:
driver current aU
B
n * high-level/input impedance (n = number of sensors to be synchronized)