Pepperl+Fuchs UC500-L2-E4-V15 Скачать руководство пользователя страница 2

Technical Data

LED green

Operating display

LED yellow

switching state

LED red

error

Electrical specifications

Operating voltage

U

B

10 ... 30 V DC , ripple 10 %

SS

No-load supply current

I

0

≤ 50 mA

Interface

Interface type

Serial interface (programming adapter required)
9600  BPS, no parity, 8 data bits, 1 stop bit

Input/Output

Input/output type

1 synchronization connection, bidirectional

0 Level

0 ... 1 V

1 Level

4 V ... U

B

Input impedance

> 12 kΩ

Output rated operating current

< 12 mA

Pulse length

0.5 ... 300 ms (level 1)

Pulse interval

≥ 14 ms (level 0)

Synchronization frequency

Common mode operation

≤ 70 Hz

Multiplex operation

≤ 90 Hz / n , n = number of sensors , n ≤ 10
(factory setting: n = 5  )

Input

Input type

1 program input

Level (switch point 1)

0 ... 1 V

Level (switch point 2)

4 V ... U

B

Input impedance

> 10 kΩ

Pulse length

2 ... 10 s

Output

Output type

1 switching output  E4, NPN, NO/NC, programmable

Rated operating current

I

e

200 mA , short-circuit/overload protected

Voltage drop

U

d

≤ 2 V

Repeat accuracy

≤ 0.1  % of full-scale value

Switching frequency

f

≤ 14 Hz

Range hysteresis

H

programmable , preset to 1 mm

Temperature influence

< 1.5  % of full-scale value

Compliance with standards and directives

Standard conformity

Standards

EN 60947-5-2:2007+A1:2012
IEC 60947-5-2:2007 + A1:2012

Approvals and certificates

UL approval

cULus Listed, General Purpose

CCC approval

CCC approval / marking not required for products rated ≤36 V

Ambient conditions

Ambient temperature

-25 ... 70 °C (-13 ... 158 °F)

Storage temperature

-40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Connection type

Connector plug M12 x 1 , 5-pin

Degree of protection

IP67

Material

Housing

PA-GF35

Transducer

epoxy resin/hollow glass sphere mixture; polyurethane foam

Mass

115 g

Factory settings

Ultrasonic sensor

UC500-L2-E4-V15

Release

 date:

 2021-03-05

 Date

 of

 issue:

 2021-03-05

 Filename:

 277756_eng.pdf

2

Germany: +49 621 776 1111

Fuchs Group

Refer to "General Notes Relating to Fuchs Product Information".

USA: +1 330 486 0001

Singapore: +65 6779 9091

www.pepperl-fuchs.com

[email protected]

[email protected]

[email protected]

Содержание UC500-L2-E4-V15

Страница 1: ...e 50 500 mm Dead band 0 35 mm Standard target plate 100 mm x 100 mm Transducer frequency approx 380 kHz Nominal ratings Response delay minimum 20 ms factory setting 55 ms Time delay before availabilit...

Страница 2: ...op Ud 2 V Repeat accuracy 0 1 of full scale value Switching frequency f 14 Hz Range hysteresis H programmable preset to 1 mm Temperature influence 1 5 of full scale value Compliance with standards and...

Страница 3: ...rogram input Synchronization 1 4 5 3 2 L L Connection Assignment 1 3 4 5 2 1 BN 2 WH 3 BU 4 BK 5 GY Wire colors in accordance with EN 60947 5 2 brown white blue black gray Ultrasonic sensor UC500 L2 E...

Страница 4: ...Female cordset single ended M12 straight A coded 5 pin PVC cable grey UB PROG2 Programming unit Microsoft NET Ultrasonic sensor UC500 L2 E4 V15 Release date 2021 03 05 Date of issue 2021 03 05 Filena...

Страница 5: ...Button for 2 s yellow LED flashes 3 Press the Programming Button for 2 s green LED flashes three times for confirmation The sensor returns to normal operation Programming Switch Points by using the P...

Страница 6: ...below If the synchronization input goes to a high level for 1 second the sensor will switch to standby mode indicated by the green LED In this mode the output s will remain in the last valid output s...

Страница 7: ...input switches the sensor to standby mode if it is parameterized for external synchronization Note Sensor response times will increase proportionally to the number of sensors that are in the synchron...