Description of Sensor Functions

Programming

The sensor is equipped with two outputs. Two trip points or trip values, as well as the output mode, can be programmed for each output. The

shape of the sensor sound cone can also be programmed. These parameters can be configured using two different methods:

- Using the sensor push buttons

- Using the IO-link interface of the sensor. This method requires an IO-link master (e.g. IO-link master01 USB) and the associated software.

The download link is available on the product page for the sensor with the IO link at www.pepperl-fuchs.de

Configuration using the push buttons is described below. To configure the parameters using the sensor IO-link interface, please read the software

description. The processes for configuring the trip points and the sensor operating modes run completely independently and do not influence one

another.

Note:

- The sensor can only be programmed during the first 5 minutes after switching on. This time is extended during the actual programming pro-

cess. The option of programming the sensor is revoked if no programming activities take place for 5 minutes. After this, programming is no

longer possible until the sensor is switched off and on again.

- The programming activities can be canceled at any time without changing the sensor settings. To do so, press and hold the push button for

10 seconds.

Programming the trip point/trip value of the analog characteristic

Note:

Each push button is assigned to a physical output. The switching output (C/Q) is programmed via push button T1. The analog output is program-

med via push button T2.

A flashing red LED during the programming process indicates unreliable object detection. Should this occur, correct the alignment of the object

until the yellow LED L1 or L2 flashes. Only then will the settings be transferred to the sensor memory.

Programming the trip points/trip values using the push button

Programming the near trip point/trip value of the analog characteristic

1. Position the object at the site of the required near trip point or trip value.

2. Press and hold the push button for 2 seconds (yellow LED flashes)

3. Briefly press the push button (green LED flashes 3 times as confirmation). The sensor returns to normal mode.

Accessories

BF 30

Mounting flange, 30 mm

BF 30-F

Mounting flange with dead stop, 30 mm

BF 5-30

Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm

V15-W-2M-PUR

Female cordset, M12, 5-pin, PUR cable

V15-W-2M-PVC

Female cordset, M12, 5-pin, PVC cable

IO-Link-Master02-USB

IO-Link master, supply via USB port or separate power supply, LED indicators, M12 
plug for sensor connection

IO-Link-Master-USB DTM

Communication DTM for use of IO-Link-Master

IODD Interpreter DTM

Software for the integration of IODDs in a frame application (e. g. PACTware)

PACTware 4.X

FDT-Framework

Microsoft .NET 

UVW90-M30

Ultrasonic -deflector

UVW90-K30

Ultrasonic -deflector

DA5-IU-2K-V

Process control and indication equipment

1   BN
2   WH
3   BU
4   BK
5   GY

Wire colors in accordance with EN 60947-5-2