background image

SI00113O-F/98/A3/15.16

71300097

Betriebsanleitung

Instruction Manual

Manuel d'instructions

Vibration Limit Switch

Vibracon LVL-M2C

ATEX:

II 1/2G Ex ia IIC T6...T3 Ga/Gb

IECEx:

Ex ia IIC T6...T3 Ga/Gb

SI00113O-F

DE –

Sicherheitshinweise für elektrische Betriebsmittel für 

explosionsgefährdete Bereiche, siehe Seite 5

EN –

Safety instructions for electrical apparatus for explosion-

hazardous areas, see page 13

FR –

Conseils de sécurité pour matériels électriques destinés aux 

zones explosibles, regardez à la page 21

Содержание SI00113O-F

Страница 1: ... IIC T6 T3 Ga Gb IECEx Ex ia IIC T6 T3 Ga Gb SI00113O F DE Sicherheitshinweise für elektrische Betriebsmittel für explosionsgefährdete Bereiche siehe Seite 5 EN Safety instructions for electrical apparatus for explosion hazardous areas see page 13 FR Conseils de sécurité pour matériels électriques destinés aux zones explosibles regardez à la page 21 ...

Страница 2: ...lettriche certificate per l utilizzo in aree con pericolo di esplosione Se il presente manuale non risulta comprensibile potete ordinarcene una copia tradotta nella vostra lingua Dichiarazione di conformità UE Con questa dichiarazione e con l applicazione del marchio CE il costruttore Pepperl Fuchs assicura che il prodotto è conforme alle direttive europee vigenti Prova della conformità è fornita ...

Страница 3: ...N 61326 1 2013 EN 61326 2 3 2013 EN 61326 2 5 2013 2014 34 EU ATEX L96 309 356 EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 60079 26 2015 2011 65 EU RoHS L174 88 110 EN 50581 2012 09 Supplemental Standards Sonstige Normen Remarks Bemerkungen EN 61010 1 2010 Affixed CE Marking Angebrachte CE Kennzeichnung 0102 Signatures Unterschriften Mannheim 2018 09 27 ppa Lutz Liebers i V Martin Holdefer Presid...

Страница 4: ...ection Probe version Length Housing A1 A2 A3 A4 A5 C2 C4 C6 E1 E2 E3 E4 E5 Electrical output AC WA Additional option Certificate E2 EB E1 EA LVL MXH XXXXX XXXXXX XX LVL MXH XXX XX XX XX XX XX Product Family Process Connection Probe version Length Housing A1 A2 A3 A4 A5 C2 C4 C6 E1 E2 E3 E4 E5 Electrical output AC WA Additional option Certificate E2 EB E1 EA LVL M2C XXXXXX XXXXXX XX LVL M2C XXX XX ...

Страница 5: ...ed documentation 14 Supplementary documentation 14 Manufacturer s certificates 14 Manufacturer address 14 Other standards 14 Extended order code 14 Safety instructions General 15 Safety instructions Special conditions 16 Safety instructions Installation 16 Safety instructions Zone 0 18 Temperature tables 19 Connection data 20 ...

Страница 6: ...osive atmospheres Explosion prevention and protection Part 1 Basic concepts and methodology Extended order code The extended order code is indicated on the nameplate which is affixed to the device in such a way that it is clearly visible Additional information about the nameplate is provided in the associated manuals Structure of the extended order code Basic specifications The features that are a...

Страница 7: ...ated metallic plates Refer to the temperature tables for the relationship between the permitted ambient temperature for the sensor and or transmitter depending on the range of application and the temperature class Modifications to the device can affect the explosion protection and must be carried out by staff authorized to perform such work by Pepperl Fuchs Probe version probe length Position Opti...

Страница 8: ... of the housing e g friction cleaning maintenance strong medium flow Basic specification feature housing option AX Avoid sparks caused by impact and friction Gas group IIC A probe coated with non conductive material can be used if avoiding electrostatic charging of the probe e g through friction cleaning maintenance strong medium flow Marked with warning sign Avoid electrostatic charging Safety in...

Страница 9: ...en interconnecting intrinsically safe circuits Connection of intrinsically safe PROFIBUS devices 10 devices Observe the maximum process conditions according to the manufacturer s documentation At high medium temperatures note flange pressure load capacity as a factor of temperature Install the device to exclude any mechanical damage or friction during the application Pay particular attention to fl...

Страница 10: ... mixtures only operate the device under atmospheric conditions Temperature 20 C to 60 C Pressure 80 kPa to 110 kPa 0 8 bar to 1 1 bar Air with normal oxygen content usually 21 V V If no potentially explosive mixtures are present or if additional protective measures have been taken the device may also be operated under non atmospheric conditions in accordance with the manufacturer s specifications ...

Страница 11: ...tight feed through Tamb Ambient temperature in C Tp Process temperature in C 1 Temperature separator or pressure tight feed through 2 Tamb 50 C to 55 C T6 3 ECTFE Temperature class Process temperature Tp process Sensor Ambient temperature Tamb ambient Electronics T6 50 C to 80 C 50 C to 70 C T5 50 C to 95 C 50 C to 70 C with temperature spacer without temperature spacer see Figure 4 T4 50 C to 125...

Страница 12: ...ed intrinsically safe fieldbus PROFIBUS PA in accordance with the FISCO model with the following maximum values Certified intrinsically safe circuit with the following maximum values Electrical connection Electronic insert Supply SI FEL55 Ui Pi Ii Ci Li 36 V 1 W 100 mA 0 0 N1 FEL56 Ui Pi Ii Ci Li 16 V 170 mW 52 mA 30 nF 0 N2 FEL58 Ui Pi Ii Ci Li 16 V 170 mW 52 mA 30 nF 0 Electrical connection Elec...

Страница 13: ...lowing document is applicable The General Terms of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Elektrotechnik und Elektroindustrie ZVEI e V including the supplementary clause Erweiterter Eigentumsvorbehalt ...

Страница 14: ... Headquarters Pepperl Fuchs GmbH 68307Mannheim Germany Tel 49 621776 0 E mail info de pepperl fuchs com For the Pepperl Fuchs representative closest to you check www pepperl fuchs com pfcontact PROCESS AUTOMATION PROTECTING YOUR PROCESS SI00113O F 98 A3 15 16 FM7 2 DOCT 0560B 115139 10 2018 71300097 ...