background image

Introduction

ICRL-U-5RJ45-G-DIN and ICRL-U-4RJ45/SFP-G-DIN are a compact 

size Ethernet unmanaged Gigabit switches, which ensure high 

switching performance and easy installation. Along with its high 

switching performance, it supports multiple internal performance 

features, such as 9K bytes Jumbo Frame, Flow Control, and it ensures 

quality traffic transmission.

The ICRL-U-5RJ45-G-DIN provides five 10/100/1000T(X) RJ45 ports. 

The ICRL-U-4RJ45/SFP-G-DIN provides four 10/100/1000T(X) RJ45 

ports and one 1000BASE-F(X) SPF port. 

The switch provides a rugged metal case design (IP31) to operate in 

harsh environments (-40 to 75°C).

It features one relay output to alarm users if power fails.

Wiring the Power Inputs

The switch provide power redundancy and polarity reverse protection. 

Use a UL Listed power supply with a recommended working voltage of 

24VDC with an input range of 10-60VDC.

PWR1 and PWR2 are dual power inputs that can be connected to 

power sources simultaneously. When the primary power source fails 

(PWR1), the system automatically switches to the secondary power 

source (PWR2), preventing any power interruption.

Both of PWR1 and PWR2 support positive electricity and negative 

electricity power systems. Please notice the power system for PWR1 

and PWR2 only accept either positive or negative electricity power 

system at one time

2

Electronic.indd   2

12/4/2019   9:16:57 AM

Содержание RocketLinx ICRL-U-5RJ45-G-DIN

Страница 1: ...Quick Installation Guide DOCT 6559 Release Date February 2020 ROCKETLINX ICRL U 5RJ45 G DIN ICRL U 4RJ45 SFP G DIN Electronic indd 1 12 4 2019 9 16 57 AM ...

Страница 2: ...in harsh environments 40 to 75 C It features one relay output to alarm users if power fails Wiring the Power Inputs The switch provide power redundancy and polarity reverse protection Use a UL Listed power supply with a recommended working voltage of 24VDC with an input range of 10 60VDC PWR1 and PWR2 are dual power inputs that can be connected to power sources simultaneously When the primary powe...

Страница 3: ...y output contacts are in the middle of the terminal block connector as shown below Insert the wires as show below to connect the relay output alarm so that it detects power fault and avoids forming a short circuit Note The relay contact only support 1A current 24VDC Pepperl Fuchs does not recommend apply higher voltage and current that over this specification 3 Electronic indd 3 12 4 2019 9 16 57 ...

Страница 4: ...e the only suitable specifications for this environment Also make sure that the distance between each node cannot be longer than 100 meters 328 feet The ICRL U 4RJ45 SFP G DIN SFP port supports hot swapping and you can change the SFP fiber transceiver without system power off This feature is useful for field site installations if the fiber signal cannot attach the other end device just change to a...

Страница 5: ...Function P1 P2 Green Power 1 2 on P F Red Power failure 1 or 2 1 5 ICRL U 5RJ45 G DIN 1 4 ICRL U 4RJ45 SFP G DIN Green Link Flashes Green Activity Amber Gigabit speed SFP ICRL U 4RJ45 SFP G DIN Green Link Flashes Green Activity Grounding the Switch There is one grounding screw on the bottom side of switch Connect the earth ground screw of the switch to the grounding surface to ensure safety and pr...

Страница 6: ...h which supports the EN 50022 DIN Rail standard 1 Insert the upper end of DIN rail clip into the back of DIN rail track from its upper side 2 Lightly push the bottom of DIN rail clip into the track 3 Verify that the DIN rail clip is tightly attached on the track 6 Electronic indd 6 12 4 2019 9 16 57 AM ...

Страница 7: ...heim Germany 49 621 766 0 info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA 1 330 425 3555 sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Company Registration No 199003130E Singapore 139942 65 6779 9091 sales sg pepperl fuchs com 7 Electronic indd 7 12 4 2019 9 16 57 AM ...

Отзывы: