background image

Quick Installation Guide

DOCT-6559 | Release Date - February 2020

ROCKET

LINX

 

ICRL-U-5RJ45-G-DIN 

ICRL-U-4RJ45/SFP-G-DIN

Electronic.indd   1

12/4/2019   9:16:57 AM

Содержание RocketLinx ICRL-U-5RJ45-G-DIN

Страница 1: ...Quick Installation Guide DOCT 6559 Release Date February 2020 ROCKETLINX ICRL U 5RJ45 G DIN ICRL U 4RJ45 SFP G DIN Electronic indd 1 12 4 2019 9 16 57 AM ...

Страница 2: ...in harsh environments 40 to 75 C It features one relay output to alarm users if power fails Wiring the Power Inputs The switch provide power redundancy and polarity reverse protection Use a UL Listed power supply with a recommended working voltage of 24VDC with an input range of 10 60VDC PWR1 and PWR2 are dual power inputs that can be connected to power sources simultaneously When the primary powe...

Страница 3: ...y output contacts are in the middle of the terminal block connector as shown below Insert the wires as show below to connect the relay output alarm so that it detects power fault and avoids forming a short circuit Note The relay contact only support 1A current 24VDC Pepperl Fuchs does not recommend apply higher voltage and current that over this specification 3 Electronic indd 3 12 4 2019 9 16 57 ...

Страница 4: ...e the only suitable specifications for this environment Also make sure that the distance between each node cannot be longer than 100 meters 328 feet The ICRL U 4RJ45 SFP G DIN SFP port supports hot swapping and you can change the SFP fiber transceiver without system power off This feature is useful for field site installations if the fiber signal cannot attach the other end device just change to a...

Страница 5: ...Function P1 P2 Green Power 1 2 on P F Red Power failure 1 or 2 1 5 ICRL U 5RJ45 G DIN 1 4 ICRL U 4RJ45 SFP G DIN Green Link Flashes Green Activity Amber Gigabit speed SFP ICRL U 4RJ45 SFP G DIN Green Link Flashes Green Activity Grounding the Switch There is one grounding screw on the bottom side of switch Connect the earth ground screw of the switch to the grounding surface to ensure safety and pr...

Страница 6: ...h which supports the EN 50022 DIN Rail standard 1 Insert the upper end of DIN rail clip into the back of DIN rail track from its upper side 2 Lightly push the bottom of DIN rail clip into the track 3 Verify that the DIN rail clip is tightly attached on the track 6 Electronic indd 6 12 4 2019 9 16 57 AM ...

Страница 7: ...heim Germany 49 621 766 0 info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA 1 330 425 3555 sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Company Registration No 199003130E Singapore 139942 65 6779 9091 sales sg pepperl fuchs com 7 Electronic indd 7 12 4 2019 9 16 57 AM ...

Отзывы: