![Pepperl+Fuchs PXV F200-B25-V1D Series Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/pepperl-fuchs/pxv-f200-b25-v1d-series/pxv-f200-b25-v1d-series_manual_1528046043.webp)
Appendix
2
0
1
5
-0
9
43
8.1.6
Code Cards for Adjusting Output 3
Parameterization enables you to assign various functions to output 3 on the read head. The
following input / output functions are available:
■
Output: None
■
Output: Overspeed message
■
Output: Warning
■
Output: Fault
■
Output: Pollution
■
Output: Event
■
Output: No position
Figure 8.27
Input/output 3 is defined as an output but has no function.
Figure 8.28
Input/output 3 is defined as an output. This output carries the potU
B
if the speed
exceeds the defined maximum speed.
Figure 8.29
Input/output 3 is defined as an output. This output carries the potU
B
as long as a
warning message is present in the read head.
Output 3: no function
Output 3: speed exceeded
Output 3: Warning