![Pepperl+Fuchs PXV F200-B25-V1D Series Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/pepperl-fuchs/pxv-f200-b25-v1d-series/pxv-f200-b25-v1d-series_manual_1528046041.webp)
Appendix
2
0
1
5
-0
9
41
8.1.5
Code Cards for Adjusting Output 2
Parameterization enables you to assign various functions to output 2 on the read head. The
following input / output functions are available:
■
Output: none
■
Output: Overspeed message
■
Output: Warning
■
Output: Fault
■
Output: Pollution
■
Output: Event
■
Output: No position
Figure 8.20
Input/output 2 is defined as an output but has no function.
Figure 8.21
Input/output 2 is defined as an output. This output carries the potU
B
if the speed
exceeds the defined maximum speed.
Figure 8.22
Input/output 2 is defined as an output. This output carries the potU
B
as long as a
warning message is present in the read head.
Output 2: no function
Output 2: speed exceeded
Output 2: Warning