PSU-IDM160-BD-

1D-J1-DC-S-N0

PSU-IDM160-BD-

1D-J1-DC-U-N0

PSU-IDM160-BD-

1D-J1-AC-S-N0

PSU-IDM160-BD-

1D-J1-AC-U-N0

Power supply 

cable

0.2 mm² … 2.5 mm² (AWG24 … AWG14), 3-pin

Data cable

0.2 mm² … 2.5 

mm² (24 AWG … 

14 AWG), 3-pin

0.2 mm² … 2.5 

mm² (24 AWG … 

14 AWG), 4-pin

0.2 mm² … 2.5 

mm² (24 AWG … 

14 AWG), 3-pin

0.2 mm² … 2.5 

mm² (24 AWG … 

14 AWG), 4-pin

Data cable max. 

length

15 m

5 m

15 m

5 m

Ambient conditions

Operating 

temperature

-25 °C to 60 °C

Storage 

temperature

-40 °C to 60 °C

Relative 

humidity

95% non-condensing

Housing 

material

Aluminum

Mechanical Data

Degree of pro-

tection

IP64

Dimensions (W 

x H x D)

140 mm x 250 mm x 56 mm

Weight

approx. 3.1 kg

2.3. Technical Data—Power Module for 2-D Handheld 

readers

PSU-IDM260-D-2D-J1-DC-S-N0

PSU-IDM260-D-2D-J1-AC-S-N0

Description

Power supply for the intrinsically safe supply of wired 2-D barcode readers 

IDM260-D-2D-J1*

electrical Data

Interfaces  field 

side (Ex e)

RS232/RS422

Interfaces  

scanner side 

(Ex i)

RS232

Operating volt-

age (nominal)

24 VDC

230 VAC

Voltage 

range

18 VDC ... 30 VDC

90 VAC ... 253 VAC

Max. power 

consumption

7.1 W

16 W

 11

  

 

T

eChnICal

 D

aTa

2018-06

  

 

T

eChnICal

 D

aTa

Содержание PSU-IDM160-BD-1D-J1-N0 Series

Страница 1: ...Manual PSU IDM160 BD 1D J1 N0 PSU IDM260 D 2D J1 S N0 Power module...

Страница 2: ......

Страница 3: ...ms of Supply for Products and Services in the Electronics Industry set out by the German Electrical and Electronic Manufacturers Association ZVEI and the Extended Reservation of Proprietorship supplem...

Страница 4: ...eld Readers 12 2 4 Use 13 3 System Structure 14 4 Commissioning 15 4 1 Installation 15 4 2 Pin assignment in the terminal compartment PSU IDM160 BD 1D J1 DC S N0 and PSU IDM260 D 2D J1 DC S N0 17 4 5...

Страница 5: ......

Страница 6: ...ding to the risk level as follows Danger This symbol warns you of an immediate and present danger If you do not observe this warning message there is a risk of personal injury and even death WARNING T...

Страница 7: ...s If you do not observe this information the intended use in explosion haz ardous areas cannot be guaranteed Observe the information given in this manual during commissioning and use of the product Th...

Страница 8: ...tion laws e g Ordinance on Industrial Safety and Health BetrSichV Do not open the device You may not make any changes to the device You may not exchange or replace any components Explosion protection...

Страница 9: ...ns and proper operation are observed Inspection The operator must appoint an electrician to check an electrically powered device in explosion hazardous areas to ensure it is in correct condition IEC 6...

Страница 10: ...J1 DC S N0 PSU IDM160 BD 1D J1 DC U N0 PSU IDM160 BD 1D J1 AC S N0 PSU IDM160 BD 1D J1 AC U N0 Description Power supply for the intrinsically safe supply of wired 1 D barcode readers IDM160 D 1D J1 an...

Страница 11: ...C Relative humidity 95 non condensing Housing material Aluminum Mechanical Data Degree of pro tection IP64 Dimensions W x H x D 140 mm x 250 mm x 56 mm Weight approx 3 1 kg 2 3 Technical Data Power Mo...

Страница 12: ...emperature 25 C to 60 C Storage temperature 40 C to 60 C Relative humidity 95 non condensing Mechanical Data Housing material Aluminum Degree of pro tection IP64 Dimensions W x H x D 140 mm x 250 mm x...

Страница 13: ...60 D 1D J1 IDM260 D 2D J1 as well as to Blue tooth base station IDMx61 B J1 BT N0 and charging cradle IDMx61 C BT N0 The corresponding system configurations of the power module with the respective han...

Страница 14: ...e a diameter of 7 mm Figure 1 Mounting points for installation 2 The connections for equipotential bonding M5 x 10 are located on both the front and back of the power module 2 Figure 2 Equipotential b...

Страница 15: ...tion in explosion hazardous areas it must be ensured that the housing is completely closed again and screwed on properly Note Changes to the wiring may only be carried out by trained and qualified per...

Страница 16: ...inal blocks in the terminal compartment Assignment for Ex e terminal compartment Terminal no Designation Description X1 L 24 V DC X2 N 0 V DC X3 PE Protective earth X4 GND RS232 X5 TxD RS232 X6 Shield...

Страница 17: ...blocks in the terminal compartment Assignment for Ex e terminal compartment Terminal no Designation Description X1 L 24 V DC X2 N 0 V DC X3 PE Protective earth X4 GND USB X5 Shield USB X6 n c X7 D USB...

Страница 18: ...s in the terminal compartment Assignment for Ex e terminal compartment Terminal no Designation Description X1 L L 100 250 V DC X2 N N Neutral conductor X3 PE Protective earth X4 GND RS232 X5 TxD RS232...

Страница 19: ...the terminal compartment Assignment for Ex e terminal compartment Terminal no Designation Description X1 L L 100 250 V DC X2 N N Neutral conductor X3 PE Protective earth X4 GND USB X5 Shield USB X6 n...

Страница 20: ...handheld scanner IDMx61 B N0 BT N0 Bluetooth base station charging cradle No explosion protection For IDMx61 Bluetooth handheld scanner IDMx61 C N0 BT N0 Charging cradle No explosion protection For ID...

Страница 21: ...spiral For IDMx60 D CBL IDM160 D J1 U S18 N0 RS232 connection cable wired 1 D handheld scanner ATEX IECEx Zone 1 21 1 8 m length smooth For IDM160 D CBL IDM160 D J1 U C38 N0 RS232 connection cable wi...

Страница 22: ...h AG XX00 surrounding enclosure HOLDER BRACKET XX00 IDMx61 B N0 Stainless steel bracket for mounting the base station IDMx61 B J1 BT N0 to the AG XX00 surrounding enclosure BAT IDMx61 M Replacement ba...

Страница 23: ...00 00 00 www pepperl fuchs com Subject to modifications Pepperl Fuchs Printed in Germany Part No 000000 00 00 00 Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www...

Отзывы: