![Pepperl+Fuchs PS1000-A6-12.16 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/pepperl-fuchs/ps1000-a6-12-16/ps1000-a6-12-16_technical-information_1527914009.webp)
Power Supply PS1000-A6-12.16
AC Input
20
21
-1
1
9
5
AC Input
Figure 5.1
Input voltage range
Figure 5.2
Turn-on behavior, definitions
AC input
Nom. AC 100-240V
Suitable for TN-, TT- and IT mains networks
AC input range
Min.
85-264Vac
Continuous operation
Min.
264-300Vac
For maximal 500ms
Allowed voltage L or N to earth Max. 300Vac
Continuous, IEC 62103
Input frequency
Nom. 50–60Hz
±6%
Turn-on voltage
Typ.
80Vac
Steady-state value, see Figure 5.1
Shut-down voltage
Typ.
70Vac
Steady-state value, see Figure 5.1
Typ.
55Vac
Dynamic value (250ms)
External input protection
See recommendations in chapter 27.3
AC 100V
AC 120V
AC 230V
Input current
Typ.
2.11A
1.74A
0.92A
At 12V, 16A, see Figure 5.3
Power factor
1
Typ.
0.99
0.99
0.96
At 12V, 16A, see Figure 5.4
Crest factor
2
Typ.
1.5
1.65
1.65
At 12V, 16A
Start-up delay
Typ.
300ms
290ms
240ms
See Figure 5.2
Rise time
Typ.
18ms
18ms
18ms
At 12V, 16A const. current load, 0mF
load capacitance, see Figure 5.2
Typ.
35ms
35ms
35ms
At 12V, 16A const. current load, 16mF
load capacitance, see Figure 5.2
Turn-on overshoot
Max.
200mV
200mV
200mV
See Figure 5.2
1
The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit.
2
The crest factor is the mathematical ratio of the peak value to RMS value of the input current waveform.
Tu
rn
-o
n
85V
Rated
input range
max.
500ms
V
IN
P
OUT
300Vac
264V
Shut
-dow
n
Start-up
delay
Rise
Time
O
ve
rs
h
oot
- 5%
Output
Voltage
Input
Voltage