Commissioning
2
0
1
8
-0
3
15
4
Commissioning
4.1
Introduction
Components
To commission the module, you require the following components:
■
WCS-PNG210 interface module
■
Connection cable from the interface module to the reader
■
Connector for the PROFINET connection to the interface module
■
Ethernet cable
■
10 VDC...33 VDC power supply
GSDML file (the GSDML file can be obtained free of charge from our website
www.pepperl-fuchs.com).
Connecting the interface module
To ensure that the assembly functions correctly, you must carry out the following steps during
commissioning:
1. Assign a PROFINET address.
2. Assign a PROFINET device name.
3. Connect the module to PROFINET using the interface labeled "RJ45 PROFINET IO".
4. To commission the process equipment (reader), please refer to its manual.
5. Ground the DIN mounting rail onto which the assembly is snapped.
6. Connect the direct current to the terminals provided.
7. Use any planning tool for project planning. The GSDML file can be downloaded from our
website: www.pepperl-fuchs.com. Simply enter the product name or item number in the
Product/Keyword search box and click Search.
Warning!
Danger to life due to defective work
Errors during installation and commissioning can cause life-threatening injuries and significant
property damage.
■
Installation and commissioning may only be carried out by trained personnel in
accordance with the safety regulations.
Note!
On delivery, the module does not yet have an IP address. In normal operation, the IP address is
usually assigned to the module by the PROFINET IO controller (PLC).
Note!
On delivery, the module does not yet have a device name. The device name is assigned to the
gateway via the project planning software.
Note!
A more detailed description of the procedure for the individual steps is provided on the
following pages.