Normal Operation
2
0
1
9
-0
2
23
8.3
Analog Voltage Output in the Event of an Error
Analog voltage output without fault values
("Error Replacement" parameter deactivated
see chapter 11.3.3)
Note!
This section only applies to devices with analog voltage output
AO: analog output in volts
V High: high voltage value
V Low: low voltage value
AD.SP1: position value setpoint 1
AD.SP2: position value setpoint 2
1: lower limit of detection range
2: upper limit of detection range
3: no damping element
4: outside of the measuring range
V Low
V High
s
AO
AD.SP1
AD.SP2
3
4
4
3
1
2
Note!
■
If the device is switched on without a damping element, the analog output is set to the low
voltage value.
■
AD.SP2 < AD.SP1 does not invert the properties. This can be set using analog output
mode. See chapter 7.1.2.