Appendix
Device Status Information
(Data Storage = no)
0x24
Device Status
R
uint8
0: Device is OK
2 = Out of
Specification
0
0x25
Detailed Device
Status
R
uint8
[9]
Active Events, see IO-
Link 1.1-Specification
Operation Information
(Data Storage = no)
0xE0
Operating Hours R
uint32 0: 0x3FFFFFFF,
Resolution 0.25 h
0.25 h
User Specific Information
(Data Storage = yes)
0x18
Application
Specific Tag
R/W
uint8
[32]
Your automation, our
passion (Modification
by user possible)
0xC0
User Tag
R/W
uint8
[32]
PMI-F90 Series
(Modification by user
possible)
Device Characteristics
(Data Storage = yes)
0xE8
1
Position Range
R
uint16 800 (PMI40)
1600 (PMI80)
2400 (PMI120)
2
Resolution
R
uint16 50
µ
m
Process Data
(Data Storage = no)
0x28
Process Data
Values
R
uint16 See Process Data
Structure
Index
Sub-
index Name
Type
Data
type
Value
Default
Unit
Note!
With the following parameter "0xEC", you can only read the complete parameter. Access to the
subindex is not possible here!
Index
Sub-
index
Name
Type
Data
type
Value
Default
Unit
Observation
(Data Storage = no)
0xEC
1
Measured Value
R
uint16
PMI40: 0 ... 800
PMI80: 0 ... 1600
PMI120: 0 ... 2400
1/20 mm
2
Signal Quality
R
uint8
0: Insufficient
1: Acceptable
2: Good
3: Excellent
3
Switching Signal 1
R
uint8
0: Inactive
1: Active
4
Switching Signal 2
R
uint8
0: Inactive
1: Active
5
Switching Signal 3
R
uint8
0: Inactive
1: Active