PGV...-F200/-F200A...-B17-V1D
Commissioning
2
0
1
7
-1
1
31
4
Commissioning
4.1
Direction Decision
The read head has several ways of following colored tapes and Data Matrix code tapes
depending on the parameterization. Depending on the input signal, the read head follows the
right-hand, the left-hand, or the better lane.
To ensure that the reader does not report any error messages after being switched on, a
direction decision must be specified. You can control the decision direction via inputs
INPUT_SELECTION_DIR_RIGHT (IN2 / DIR_RIGHT) and INPUT_SELECTION_DIR_LEFT
(IN1 / DIR_LEFT) or via the protocol. See chapter 3.3.
Direction Decision via Input Signal
Figure 4.1
Direction decision via protocol
Direction control via the protocol. See chapter „Modules with Input Data“ on page 43.
If direction decisions are made via the protocol, subindex 12 "Input Source Selection" must be
switched to Software.
Input 2
INPUT_SELECTION_DIR_LEFT
Input 1
INPUT_SELECTION_DIR_RIGHT Direction Decision
0
0
No lane is selected
Error code 5
0
1
Follow right-hand lane
1
0
Follow left-hand lane
1
1
Colored tape: follow
lane with better quality
Data Matrix code tape:
follow lane with more
detailed position
information
Data Matrix tag: no
significance
Table 4.1
t
1
0
1
0
INPUT_SELECTION_DIR_
RIGHT
INPUT_SELECTION_DIR_
LEFT
Direction decision
≥ 20 ms
Error 5
Left
Error 5
Left
Right
Note!
If direction decisions are sent to the reader via a protocol, the input signals from the hardware
input are ignored until the reader is reset. .