Operation and Communication
7.1.6
Global Primary Data
Global primary data allows you to parameterize the reader using PROFIBUS. Global primary
data is always transferred to the reader in full.
Designation
Function
Parameter data
Primary data
X resolution
Multiplier for the length in the
direction of the X coordinate
Resolution
0.1 mm
1 mm
10 mm
Y resolution
Multiplier for the length in the
direction of the Y coordinate
Resolution
0.1 mm
1 mm
10 mm
Angle resolution
Multiplier for the angle output
Resolution
-16,384
–
0
–
16,384
360
Horizontal offset
Offset in the direction of the X
coordinate
Length
0 mm
–
±
10,000,000 mm
Vertical offset
Offset in the direction of the Y
coordinate
Length
0 mm
–
±
10,000,000 mm
Angle offset
Line of vision offset
Angle
-16,383
–
0
–
16,383
No position value X X value if no code tape is visible
X data at "No
Position"
Last valid
position
specified value
(
0
–
0xFFFF
FFFF
hex
)
No position value Y Y value if no code tape is visible
Y data at "No
Position"
Last valid
position
specified value
(
0
–
0xFFFF
FFFF
hex
)
No position value
angle
Angle output if no colored tape is
visible
Angle data at "No
Position"
Last valid angle
specified angle
(
0
–
0xFFFF
hex
)
Bandwidth
Width of the colored tape
Width
10 mm
–
40 mm
18 mm
Color
Color of the tape
Color
1 = blue (RAL
5015)
2 = green
(RAL
6032)
3 = red (RAL
3001)
4 = Yellow (RAL
1021)
Table 7.2
Bold
= default values