![Pepperl+Fuchs PCV F200-B16-V15 Series Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/pepperl-fuchs/pcv-f200-b16-v15-series/pcv-f200-b16-v15-series_manual_1528035037.webp)
Operation and communication
2
0
1
5
-0
9
37
7
Reserved
Reserved
unsigned8
ro
-
8
Output1
Function
Meaning of
the output
signal at
output 1
unsigned8
rw
0x00: No
Function
0x01:
Overspeed
0x02: Warning
0x03: Error
0x04: Dirty
0x05: Event
0x06: No
Position
0x07: Repair
Strip
9
Output1
Overspeed
Value
Speed at
which output 1
is activated
unsigned32
rw
0
–
65,534
cm/s
125 cm/s
10
Output2
Function
Meaning of
the output
signal at
output 2
unsigned8
rw
0x00: No
Function
0x01:
Overspeed
0x02: Warning
0x03: Error
0x04: Dirty
0x05: Event
0x06: No
Position
0x07: Repair
Strip
11
Output2
Overspeed
Value
Speed at
which output 1
is activated
unsigned32
rw
0
–
65,534
cm/s
125 cm/s
12
Output3
Function
Meaning of
the output
signal at
output 3
unsigned8
rw
0x00: No
Function
0x01:
Overspeed
0x02: Warning
0x03: Error
0x04: Dirty
0x05: Event
0x06: No
Position
0x07: Repair
Strip
13
Output3
Overspeed
Value
Speed at
which output 3
is activated
unsigned32
rw
0
–
65,534
cm/s
125 cm/s
14
No Position
Value X
X value if no
code tape is
visible
Array of
unsigned8
Bytes 0 - 3
rw
0x00: Last
Valid Position
0x01:
Specified
Position
Specific Value
X
Specific X
value
Bytes 4 - 7
rw
0 mm
-
10,000,000
mm
Subindex
Designation
Function
Data type
Attribute
Primary data