Pepperl+Fuchs OIT F113-B12-CB Series Скачать руководство пользователя страница 32

19

9165

 201

3-

06

32

OIT***-F113-B12-CB*

Communicating with the OIT system

7.3

TCP/IP Communication with Easy Mode:

The TCP/IP protocol enables communication between the PLC and OIT system. 
For communication in Easy Mode, the host system connects to the OIT system via 

port address: 10100

. The OIT system initially waits for a trigger signal when 

starting communication in Easy Mode. There are two different trigger signals:

Once one of the two trigger signals has been triggered, the OIT system captures 

an image. After the image has been successfully captured, the OIT system 

decodes the data stored on the read-only tag and sends this data to the PLC. If 

the read-only tag was not successfully read, the OIT system sends a "read error" 

to the PLC. The OIT system then waits for another trigger signal.

Figure 7.1

Easy Mode flow chart

Telegram structure:

The data telegram has a fixed length. The code read on the read-only tag is sent 

to the PLC in ASCII characters. If the code read on the read-only tag has less than 

six characters, leading zeros are added to the code. For example, the number 123 

is sent as 000123.

Successful Read of the Read-only Tag

Unsuccessful Read of the Read-only Tag

Trigger signal from an external trigger sensor (positive edge)
or
Trigger signal via the PLC telegram.

Trigger

Send data

Byte 0

Bytes 1

6

Bytes 7

10

Byte 11

Byte 12

Byte 13

Start character

Code number

Status

Checksum

End character 

1

End character 

2

#(23 hex)

000001 to 

999999

See status 

table

Value x

CR (0D hex)

LF (0A hex)

Byte 0

Bytes 1

6

Bytes 7

10

Byte 11

Byte 12

Byte 13

Start character

Code number

Status

Checksum

End character 

1

End character 

2

#(23 hex)

NOREAD 

(ASCII)

See status 

table

Value x

CR (0D hex)

LF (0A hex)

Содержание OIT F113-B12-CB Series

Страница 1: ...OIT F113 B12 CB Identification system for high temperatures up to 500 C FACTORY AUTOMATION MANUAL ...

Страница 2: ...erms of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its most recent version as well as the supplementary clause Expanded reservation of proprietorship OIT F113 B12 CB ...

Страница 3: ...package 14 4 7 Accessories 14 4 7 1 Power supply 14 4 7 2 Connecting cables for trigger sensor and external illumination 15 4 7 3 Network cable 16 4 7 4 Code Sheets 17 5 Installation 18 5 1 Preparation 18 5 2 Mounting the Device 18 5 3 Connecting the unit 20 5 4 Storage and transport 22 6 Commissioning 23 6 1 Alignment Adjustment 23 6 2 Programming 26 7 Communicating with the OIT system 27 7 1 TCP...

Страница 4: ...ontrol file menu 56 9 3 1 Display OITControl menu Adjust language 56 9 4 OITControl Configuration menu 56 9 4 1 OITControl configuration menu User administration 57 9 4 2 OITControl configuration menu Customizing the log view 61 9 4 3 OITControl configuration menu Configure OITControl 61 9 4 4 OITControl configuration menu Configure OIT system 65 9 4 5 OITControl configuration menu Start up 71 9 4...

Страница 5: ...gy on a worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the device its functions or accessories please contact us at Pepperl Fuchs GmbH Lilienthalstraße 200 68307 Mannheim Telephone 49 621 776 4411 Fax 49 621 776 274411 E Mail fa info pepperl fuchs com Not...

Страница 6: ... developed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system that conforms to ISO 9001 Note A Declaration of Conformity can be requested from the manufacturer ISO9001 ...

Страница 7: ...d use The operating company bears responsibility for observing locally applicable safety regulations Installation and commissioning of all devices must be performed by a trained professional only User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability If serious faults occur stop using the device Secure the device against inadvertent...

Страница 8: ...apid entry Pluggable connections for the rapid exchange of devices and a controller with simple command set via the Ethernet interface guarantee simple operation A scratch resistant replaceable quartz glass panel and sturdy metal housing make the OIT a robust efficient identification system Figure 4 1 OIT systems The OIT system is integrated in a single compact component The camera illumination un...

Страница 9: ...amera as well as a built in infrared LED board for correct illumination of the metal plates The OIT300 F113 B12 CB2 is specially designed to recognize small code sheets OIC CB2 4 2 3 OIT500 F113 B12 CB The OIT500 F113 B12 CB is designed for a read distance between 200 mm and 450 mm to the read only codes measured from the front lens on the OIT system The OIT system is equipped for this task with a...

Страница 10: ... if the image taken is recognizable However when ambient conditions worsen camera image too bright dark too many structures in the image object almost too far too near low contour object just barely in image area a read error can be ex pected 5 Ready Flashes while initializing approximately 30 seconds During this time a Data Matrix code can be read in to re program the unit No network connection t...

Страница 11: ...e external illumination The following diagram shows the pin assignment Figure 4 5 External illumination pin assignments 1 Grounding screw 2 Power supply Harting HAN Q 8 0 F plug 3 Network RJ45 network socket with push pull connector for IP65 4 Trigger sensor 4 pin M12 socket 5 External illumination 4 in M12 socket 1 Grounding screw 2 Trigger sensor 4 pin M12 socket 3 Network RJ45 network socket wi...

Страница 12: ...nsor pin assignments Network connection On the side of the housing of the OIT system is a network jack for connecting an RJ45 network plug The pin assignments are shown in the following illustration Figure 4 7 Network connection pin assignments 1 24 V trigger sensor power supply 2 Not assigned 3 Ground GND 4 Trigger signal TRIG 1 Transmit data 2 Transmit data 3 Receive data 4 Not assigned 5 Not as...

Страница 13: ...factory presets To galvanically isolate both switches must be positioned to the left After that Pin2 and Pin5 must be powered by a different power supply than the OIT 1 n c reserved 2 Ground for separate I O supply GND IO 3 Mode bit 1 MOD 1 4 Mode bit 0 MOD 0 5 24 V supply for separate I O 24V_IO 6 24 V supply to device 24 V 7 n c reserved 8 Device ground GND 1 2 3 8 5 4 6 7 Note Resetting the Par...

Страница 14: ... the read code carrier ID and display of the transmitted data and control bits Operator terminal for troubleshooting incorrect reading operations Parameterization and maintenance of the OIT system Diagnosis of the OIT system You can download the latest version of the OITControl software and view additional information at http www pepperl fuchs com 4 6 Delivery package OIT F113 B12 CB Mounting base...

Страница 15: ...1 W 5 m V1 G 5M PVC V1 G V1 G 5M PVC V1 W 10 m V1 G 10M PVC V1 G V1 G 10M PVC V1 W M12 socket angled 4 pin PUR 2 m V1 W 2M PUR V1 G On request 5 m V1 W 5M PUR V1 G On request 10 m V1 W 10M PUR V1 G On request Order number Description mm2 Cable V1 G Straight M12 socket 4 pin max 0 75 4 to 6 mm V1 G PG9 Straight M12 socket 4 pin max 0 75 6 to 8 mm V1 W Angled M12 socket 4 pin max 0 75 4 to 6 mm V1 W...

Страница 16: ...e OIT system does not ensure IP65 protection and the regular removal of the network plug may not be possible In order to ensure IP65 protection use a HARTING RJ Industrial IP67 Push Pull Connector Do not use the connector style Variant 14 Model Description V45 G RJ45 network jack without cable V45 GP RJ45 network jack with push pull connector IP65 without cable V45 GP 10M PUR ABG V45 G Connecting ...

Страница 17: ...This steel code sheet is suitable only for applications in which the surface of the code sheet is protected against corrosion by means of a coating e g paint Rust will have a considerable impact on the quality of the reading OIC C10V2A CB1 Read only tag for optical high temperature identification system stainless steel Value range 6 digit number between 000 000 and 999 999 plus one check digit OIC...

Страница 18: ...ents If you have any questions please contact Pepperl Fuchs 3 Keep the original packing material in case you need to store or ship the unit at a later time 5 2 Mounting the Device The device has a preassembled mounting base with four M6 threads positioned symmetrically on the base of the housing to allow easy installation of the OIT system in your plant The following illustration shows all the rel...

Страница 19: ...tallation 199165 2013 06 19 Figure 5 2 Dimensions of the OIT200 system Figure 5 3 Dimensions of the OIT1500 system 270 297 116 68 153 189 177 4 ø 5 4 4x 188 6 168 41 45 98 10 68 20 202 256 170 53 ca 80 57 57 ca 100 M6 4x ...

Страница 20: ...g plug on the side of the housing 2 Pull the protective sleeve over the connector until it locks in place This protects the supply cable from being inadevertently pulled out 60 mm 140 mm 65 mm 100 270 mm 170 mm 270 440 mm 200 450 mm 170 mm 370 620 mm 1000 1500 mm 170 mm 1170 1670 mm 140 mm 200 mm OIT500 OIT300 OIT200 OIT1500 Note Mounting Code Sheets on the OIT300 OIT500 and OIT1500 Ensure that th...

Страница 21: ...o use the configuration data provided in the Network configuration overview table see table Network configuration overview OIT on page 29 Connecting a trigger sensor To connect a trigger sensor proceed as follows Plug the 4 pin M12 plug into its corresponding jack on the side of the housing Note Documenting the network configuration The OIT system uses the TCP IP protocol to communicate with the P...

Страница 22: ...For storage and transport purposes package the unit using shockproof packaging material and protect it against moisture The best method of protection is to package the unit using the original packaging Furthermore ensure that the ambient conditions are within allowable range ...

Страница 23: ... you will be using this distance you can disregard the following settings see chapter 5 2 Setting optimal illumination angle In order to set the optimal illumination angle proceed as follows 1 Unscrew the OIT enclosure cover 2 Loosen the 2 screws at the base of the illumination unit see Position 1 Figure 6 1 Setting the illumination angle 3 Slide the illumination unit to the same distance as the O...

Страница 24: ...rture of the lens This only needs to be done for very fast code sheet movements even when changes to the camera shutter time and camera gain in OITControl do not lead to the desired results Read only tag too dark Figure 6 2 Focusing the image 6 Once the image sharpness has been correctly set gently tighten the screws on the lens 7 Screw the enclosure cover back down The following inages show a pic...

Страница 25: ...4 Check the illumination of the code carrier If the camera image is too dark increase the camera gain Also check the LED display on the illumination unit Stability or the LED indicator in the OITControl software OIT warnings both have the same functions If the LED lights up then the gain is set too high The settings made can be applied to all other OIT systems in the same environment The OIT syste...

Страница 26: ...or approx 30 seconds 2 Hold a Data Matrix code containing the new encoded operating parameters at a defined distance in the field of the OIT system Hold the Data Matrix code at a distance of about 300 350 mm in front of the OIT system Once the OIT system detects the code the data is adopted as the new operating parameters and is written into the parameter file The COK LED flashes for approx 5 seco...

Страница 27: ...instructions see chapter 7 3 TCP IP communication over a web browser Diagnosis Here a connection to the internal OIT system web browser can be made on which different information about the OIT system is located see chapter 7 4 TCP IP communication over FTP diagnosis a connection to the internal FTP server of the OIT system can be made on which the fault patterns are located see chapter 7 5 7 1 TCP...

Страница 28: ...lowing control bits are transmitted from the PLC to the OIT system in the control byte SAH 0 Default state to OIT prompts a reset of the OIT system 1 Read to OIT prompts a read operation 2 Current data to OIT Info to OIT system that matches a data set in the data sent to the OIT system Afterwards the read cycle ends 3 No data to OIT info to OIT system that does not match a data set in the data sen...

Страница 29: ...d Control byte STH 1 byte The individual control bits that are transmitted from the PLC in the control byte SAH are mirrored in the control byte STH Manual entry ID UID 14 bytes Manually captured data is transmitted in this block during a failed read ID up to 6 bytes are available UID up to 8 bytes are available If the data was not entered manually a is transmitted for every byte read ID number 6 ...

Страница 30: ... the OIT system the PLC will send the message No data to OIT to the OIT system SAH 3 This will end the complete read cycle 7 1 2 Example Read error in a read only tag read The communication for a read error between the PLC and the OIT system is illustrated below 1 The PLC sends the OIT system the command to read out a read only tag Read to OIT SAH 1 2 Depending on the settings the OIT system eithe...

Страница 31: ...chnology Here specific data packets that indicate length beginning and end must be used Data transfer takes place message oriented with RFC1006 Thus only closed message blocks are sent through a connection and are recognized as such by the receiver RFC 1006 now specifies which information must be added to the transmitted data in the form of a header in order to ensure this So RFC 1006 makes messag...

Страница 32: ...system then waits for another trigger signal Figure 7 1 Easy Mode flow chart Telegram structure The data telegram has a fixed length The code read on the read only tag is sent to the PLC in ASCII characters If the code read on the read only tag has less than six characters leading zeros are added to the code For example the number 123 is sent as 000123 Successful Read of the Read only Tag Unsucces...

Страница 33: ...o many structures in image Bit 3 The distance between the read only tag and OIT system is too great Bit 4 The distance between the read only tag and OIT system is too small Bit 5 Not enough contrast Bit 6 The read only tag is outside of the detection capture range 0x01 OIT status The read only tag could no longer be read No punched holes found 0x02 Few punched holes found first loop 0x03 Few punch...

Страница 34: ...e web browser includes Last image Displays last image processed Last error image Displays last error image History Displays history Results statistical evaluation of reads and read errors in the last days weeks months and total Permanently set parameters OIT OIT system information Decoding Image capturing Inspection Image capture and testing information Ethernet Network connections information Com...

Страница 35: ...he device log_0 text file in which all log data is stored As soon as the file becomes too large another log file with a higher number is created errimg_0000000001 program file that stores the fault patterns If there are more fault patterns they are filed under an ascending number oitdat files all set parameters as a binary file A password is necessary to establish an FTP connection to the OIT syst...

Страница 36: ...ics 8 1 Installing OITControl The minimum hardware and software requirements are detailed below Processor Pentium III 1 GHz Working memory at least 512 MB RAM Hard disk space at least 10 GB Java Runtime Environment version 1 5 or later The latest version of the software can be found on our homepage at www pepperl fuchs com Installing OITControl To install the OITControl software on the computer pr...

Страница 37: ...ndard functions to adapt the OITControl user interface to your equipment by modifying the file OITControl xml The following refer to the software version in its initial state Figure 8 1 Start screen of OITControl The header is displayed at the top of the screen The right part of the header contains the familiar icons to minimize maximize and close the program The left side of the header shows OITC...

Страница 38: ...smitted from the OIT system to OITControl and arranged and displayed there as individual information blocks The following information is displayed in the default configuration Read cycle OIT including the individual control bits Request reset read error ID read Read cycle PLC including the individual control bits Reset read start current data no data OIT LED status including the status LEDs Power ...

Страница 39: ...egram begins at Position 262 and is 6 characters long The most recently generated image is also displayed OIT debug display The OIT system evaluates the captured images with regard to several factors If the captured image is recognizable and a read error occurs due to a deterioration of the ambient conditions then the tab OIT debug display OIT Debug display will provide further information as to p...

Страница 40: ...d to the drop down list by changing the file OITCamera XML see chapter 11 1 If a new connection to an OIT system is established at the next program start the most recently used connection will be offered by default in the drop down list last used last used 3 Click OK OITControl checks whether the desired OIT system is available establishes the connection and waits for confirmation from the OIT sys...

Страница 41: ...OIT system A connection between OITControl and an OIT system is called a socket connection No more than 2 socket connections are possible at any one time If attempting a third socket connection the following error message is generated The connection request was denied by the OIT system The following OITControls are already connected to the OIT system The connected OITControl socket connections wil...

Страница 42: ...n stops and the dialog window is closed If needed start the Live image set up over The number of live images can be changed in the menu at Configuration Configure OIT system Align the OIT system and adapt if needed the settings field of view sharpness brightness image contour etc to the requirements of your equipment and check the settings by means of the live images in OITControl 5 Once the OIT s...

Страница 43: ...re sent to the PLC Figure 8 7 Dialog box Commissioning OIT system Correct read errors Repeat read operation An instance may occur when the OIT system cannot read the data from a read only tag in a read operation through the PLC In this case the buttons Manual entry of ID UID number s and Repeat read operationwill flash in the tool bar Proceed as follows in order to correct the read error by repeat...

Страница 44: ...ta entry will open Figure 8 8 OITControl Manual data input 2 Enter the ID number of the read only tag into the box Entry box for ID number Enter the check digit of the read only code into the second box Optionally the UID number may also be entered For example a defective read only tag is replaced by a new read only tag that merges with the UID number to create a unique identification code 3 Click...

Страница 45: ...tool bar Predefined user roles OITControl comes with the following predefined user roles User roles Password User permissions Pepperl Fuchs pf View all information Manual input for failed reads Set the date and time on the OIT system Pepperl Fuchs Primary User pfhaupt View all information Manual input for failed reads Set the date and time on the OIT system Configure the OIT system excluding frame...

Страница 46: ...eterizing the OIT system The OIT system is parameterized using an existing Data Matrix code see chapter 6 2 Open the parameter file It is possible to load previously stored parameters into OITControl and transfer them to the OIT system Proceed as follows 1 Select Configuration configure OIT System The window invalid parameters will open saying that no valid parameter data is yet available Note Use...

Страница 47: ... in Parameter set The dialog window Open will open 4 Select the stored parameterization 5 To confirm the selection click on Open The dialog window Open will close The settings from the parameter file are displayed in the dialog window Parameterization of the OIT system 6 In order to send the settings to the OIT system click the button Write parameters in the OIT system 7 In order to close the para...

Страница 48: ...ration Configure OIT System 2 If the window Invalid parameters pops up close it by clicking on OK A dialog window Parameterization of the OIT system will open Figure 8 13 Network tab 3 In the area Ethernet change the settings for IP address Subnet Mask and Gateway in the appropriate fields according to the requirements of your network 4 If a clock server is going to be used enter the IP address of...

Страница 49: ...em click the button Write parameters in the OIT system 7 In order to close the parameterization of the OIT system dialog window click on end Activate TNR To activate the TNR bit in the STL block of the data telegram to the PLC proceed as follows 1 Select Configuration Configure OIT System 2 If the window Invalid parameters pops up close it by clicking on OK 3 Go to the tab Image Check Figure 8 15 ...

Страница 50: ... OIT system will then trigger a read operation with a rising edge at the trigger entrance 5 In order to send the settings to the OIT system click the button Write parameters in the OIT system 6 In order to close the parameterization of the OIT system dialog box click on end Saving a parameter file It is possible to save the settings in the OIT system parameterization dialog box for future use To c...

Страница 51: ...ms can be closed Under Process commands can be sent to the OIT system Under Display the interface language can be set Under Configuration all configurable parameters can be set Under help can be found 9 1 OITControl file menu Figure 9 2 Menu bar OITControlFile Configuration loading XML files Connect to the OIT system establishing connections to the OIT system Disconnecting an available connection ...

Страница 52: ... When cueing the function Connect to the OIT system all available IP addresses for selection will be displayed 9 1 2 ITControl file menu Connect to OIT system Figure 9 4 Select OIT system dialog box left input area Either the IP address last used or the IP address of the OIT system can be manually entered using the drop down list in the left input area More OIT systems can be added to the drop dow...

Страница 53: ...A dialog window opens in which the image file to be opened can be selected 9 1 5 OITControl file menu Exit The connection to the OIT system is disconnected the socket connection is closed and the program ended 9 2 Edit OITControl menu Figure 9 6 Menu bar OITControl Edit Manual entry If a read only tag is not recognized the code may be manually entered here Repeat read operation If a read only tag ...

Страница 54: ...r input box the check digit of the read only tag is manually entered here Right input box The UID code is entered here For example a defective read only tag is replaced by a new read only tag that merges with the UID number to create a unique identification code The input boxes can still be defined under Configuration Configure OITControl Manual entry There an optional preliminary check of the ent...

Страница 55: ...Control the administrator or primary user has the option of checking the alignment of the OIT system the display window and its sharpness image brightness and contrast and if necessary adapting them to the needs of their equipment There is also the option in the drop down menu to display fault patterns and an evaluation with or without the hole recognition markings A partial image can be pre defin...

Страница 56: ...isplay areas are customized to your particular needs through an XML file which also controls the language 9 4 OITControl Configuration menu Figure 9 12 Menu bar OITControl Configuration User administration select change log out and delete users Customize login customizing the login Configure ITControl all OITControl parameters can be set Configure OIT system all OIT system parameters can be set St...

Страница 57: ...ogs off the current user Adding users adding new users This can only be done by an administrator or primary user Deleting users deleting a user with passsword access 9 4 1 1 OITControl configuration menu User administration Select user Figure 9 14 selecet user dialog box The current user is logged off and another user is logged on Select the new user to be logged on from the drop down menu Additio...

Страница 58: ...User permissions Pepperl Fuchs pf View all information Manual input for failed reads Set the date and time on the OIT system Pepperl Fuchs Primary User pfhaupt View all information Manual input for failed reads Set the date and time on the OIT system Configure the OIT system excluding frame definitions Configure OITControl Pepperl Fuchs Administrator pfadmin View all information Manual input for f...

Страница 59: ...another user is logged on Further actions can only be carried out after logging on again 9 4 1 4 OITControl configuration menu User administration Add user Figure 9 17 add user dialog box Add new users here It will be necessary to enter a new user name and password The clearance level of the new user can be selected directly from the drop down menu Clearance level A concise description is recommen...

Страница 60: ...rator can delete other user accounts Level User rights deactivated none guest View all information User View all information Manual entry for failed incorrect reads Set date and time in OIT system Primary user View all information Manual entry for failed incorrect reads Set date and time in OIT system Configure the OIT system with exception of the telegram definition Configure OITControl Administr...

Страница 61: ...ware see chapter 9 4 8 9 4 3 OITControl configuration menu Configure OITControl Figure 9 20 OITControl konfigurieren dialog box Launch program Display of all important components at the start of the program Directories Information on the directory structure can be found here Manual entry Definition of the dialog window input mask Manual entry Image display sets the size of the partial image and th...

Страница 62: ...rator or primary user is logged off and only a standard user remains active Autom disconnection change the time after which OITControl disconnects from the OIT system Last connected OIT system displays the IP adress and IP port of the last connected OIT system A Ping test can be activated here Window displays the program window position Configuration files set the configuration files that automati...

Страница 63: ... directories to be stored Image directories Here you set up the folder for the image directories to be loaded and the image directories to be stored 9 4 3 3 OITControl configuration menu Configure OITControl Manual entry tab Figure 9 23 Manual data input tab ID box Definition of the ID box in the dialog window Manual entry Checksums box Definition of the checksum box in the dialog window Manual en...

Страница 64: ...nly an adjustable part of it may be shown Live image display sets the maximum number of live images The Live image dialog box closes after showing the number of live images 9 4 3 5 OITControl configuration menu Configure OITControl Data Matrix tab Figure 9 25 DataMatrix tab The settings in the menu Configure OIT system can be printed out in a Data Matrix code The DOT size of the Data Matrix code a...

Страница 65: ...trol and the OIT system 9 4 4 OITControl configuration menu Configure OIT system Figure 9 27 Parameterization of the OIT system dialog box Network network connections information RFC1006 sets the TSAP HOST and TSAP OIT identifiers OIT telegram OIT telegram settings Control telegram control telegram settings Image Testing settings for all code recognition Image defines the area in which the code sh...

Страница 66: ...server Displays the IP address of an NTP server The Network Time Protocol NTP is a standard to synchronize clocks in computer systems through packet based communication nets As a rule NTP uses the transport protocol UDP It was specially developed to give reliable clock time in networks with variable packet run time But the transport protocol TCP can also be used Moreover the right time zone can be...

Страница 67: ...SAP OIT Displays of communication access point on the OIT system page in Ascii characters or Hex characters 9 4 4 3 OITControl configuration menu Configure OIT system OIT telegram tab Figure 9 30 OIT telegram tab Telegram Adapting the OIT telegram to the present OIT system Note No changes to the default values Make no changes to these values if possible That would change the protocol and could pre...

Страница 68: ...sent control Note Changes only with administrator rights Changes can only be entered here when logged on as an administrator Note No changes to the default values Make no changes to these values if possible That would change the protocol and could prevent new connections to the systems from being established Note Changes only with administrator rights Changes can only be entered here when logged o...

Страница 69: ...t TNR bit The maximum number of identical codes that can be detected in succession can be set under Max permitted identical code If you set this to two the system will read a code twice consecutively before generating an error message If a 0 is entered then the function is disabled LED illumination the external illumination is switched on here To do this an external illumination must be connected ...

Страница 70: ...ted Only this section is used by the camera for the code search To select a section draw a box around the area required for evaluation using the mouse Note Resetting the Parameterization Lock You can reset the activated parameterization lock by applying a logical high to the pin 3 mode bit 1 MOD 1 and a simultaneous logical low to the pin 4 mode bit 0 MOD 0 After applying this logic level to the i...

Страница 71: ... in the ID area and in the Read modearea the read mode can be switched to either direct read or trigger read If the trigger read mode has been selected but the trigger does not appear then the button Normal position will lead back to the initial situation A complete read operation can be run in the Automaticarea Here you can setthe number of seconds after which a new read operation wil start If no...

Страница 72: ... 36 Menu box OITControl Configuration OIT system time Read OIT system time The currently set system time of the OIT system can be read out Check the indicated data after successful data transmission date and time If the difference is too great then the time between the OIT system time and computer time can be synchronized Update OIT system time The currently set system time of the OIT system can b...

Страница 73: ...stem Logging dialog box The OIT system log file is displayed in this dialog window 9 5 OITControl help menu Figure 9 38 Menu bar OITControl Help starting Online help through Display all relevant program information 9 5 1 OITControl menu Help Figure 9 39 Helpdialog box Part of the documentation may be accessed as online help ...

Страница 74: ...199165 2013 06 74 OIT F113 B12 CB OITControl menu structure 9 5 2 OITControl menu over Figure 9 40 About dialog box Displays all relevant program information ...

Страница 75: ...he LED display Check alignment on the right side of the OITControl user interface If the LED lights up please check the illumination and alignment of the code carrier using the live image display 3 Open the tab OIT debug display on the right side of the OITControl user interface All important messages concerning the entire OIT system appear there 4 Analyze the fault pattern Look at the fault patte...

Страница 76: ...as is in OITCamera Do not change this file name Any number of OIT systems with their IP addresses can now be added to the subfolder Cameras Adding a new OIT system 1 Copy one of the two already existing folders 2 Write the IP address of the new OIT system in the copied folder 3 Set the IP port to the value at which the OIT system was configured default 10050 4 Any OIT system name can be entered un...

Страница 77: ...egram Message counter position Size 0 2 Control byte STL position Size 2 1 Control byte STH position Size 3 1 TNR number manual position size 4 6 FSNR number manual position size 10 8 ID number position size 18 6 Status fault message 24 4 Control telegram Data set position size 0 224 Message counter SPS position size 224 2 Control byte SAL position size 226 1 Control byte SAH position size 227 1 I...

Страница 78: ...199165 2013 06 78 OIT F113 B12 CB Appendix The following Data Matrix code may also be used to set the default values See chapter 8 5 and See chapter 6 2 ...

Страница 79: ...endix 199165 2013 06 79 11 3 FTP connection using FileZilla software When using FileZilla software make sure you configure the following settings Use active mode Only allow one connection Figure 11 1 Adjustment FileZilla ...

Страница 80: ...mbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Company Registration No 199003130E Singapore 139942 Tel 65 67799091 E mail sales sg pepperl fuchs com 199165 TDOCT1186E_ENG 06 2013 ...

Отзывы: