Страница 1: ...Laser Class 2M EN 60825 1 ODT MAC400 ODT MAC401 ODT MAC403 Stationary reader for all common 1D and 2D barcodes FACTORY AUTOMATION MANUAL...
Страница 2: ...livery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its most rece...
Страница 3: ...Cables 11 4 5 2 Other accessories 11 5 Installation 12 5 1 Preparation 12 5 2 Mounting 12 5 3 Connecting the device 13 5 4 Assigning an IP address to a network connection using Windows XP 14 5 5 Stor...
Страница 4: ...technology on a worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any question...
Страница 5: ...duct was developed and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance...
Страница 6: ...afety instructions Class 2 laser product This device is a class 2 laser product Standards IEC 60825 1 2007 certified Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser No...
Страница 7: ...op using the device Secure the device against inadvertent operation In the event of repairs return the device to your local Pepperl Fuchs representative or sales office Warning Visible red class 2 las...
Страница 8: ...onary reading device can be configured easily and quickly using a normal web browser via the standard Ethernet interface or a series connection Support is also provided for the mechanical alignment of...
Страница 9: ...cessful read good read Red The LED flashes red after an unsuccessful read bad read 4 1 2 3 LAN TCP IP ST VGA VCC I O RS232 PIN Signal Description 1 2 GND GND for device 3 IO GND GND for inputs outputs...
Страница 10: ...on 1 OUT Vsync Vertical synchronization output 2 GND RGB Red signal green signal and blue signal ground 3 OUT R Red signal output 4 OUT G Green signal output 5 GND Horizontal synchronization output gr...
Страница 11: ...DEO Video connection cable cylindrical connector 7 pin on SUB D socket 15 pin VGA 2 meters ODZ MAC CAB 15POL 2 5M FEMALE Connection cable Sub D socket 15 pin 2 5 meters can be pre assembled ODZ MAC CA...
Страница 12: ...rial in case you need to store or ship the unit at a later time 5 2 Mounting Please refer to the technical data in the data sheet for the read distance ODT MAC400 Figure 5 1 Dimensions of the straight...
Страница 13: ...nect the power supply to the appropriate pins on the Sub D socket The power supply has now been connected To connect the power supply to the device quicker the pre configured connection cable can also...
Страница 14: ...sensor proceed as follows Connect the trigger sensor to the cable previously connected for the power supply 5 4 Assigning an IP address to a network connection using Windows XP To assign an IP addres...
Страница 15: ...ion 216677 2012 05 15 3 Select the Internet Protocol TCP IP element from the Properties dialog box by double clicking on it The TCP IP properties dialog box will open 4 In the TCP IP properties dialog...
Страница 16: ...operties page and the LAN connection properties page using OK and Close This completes the network configuration and the sensor can be used 5 5 Storage and transport For storage and transport purposes...
Страница 17: ...andard web browser Aligning the stationary reader To find the ideal alignment for the device use the two laser diodes in the stationary reader 1 Supply power to the reader via the D Sub connector 2 Ad...
Страница 18: ...ons Starting the operator interface To start the operator interface proceed as follows In the input field of a standard web browser enter the IP address of the stationary reader 192 168 2 2 and press...
Страница 19: ...is a pictorial representation of a status LED This status LED lights up green when a device is connected Otherwise it is red Activating live image capture To activate live image capture click the Sta...
Страница 20: ...used to set the duration of the flash at intervals of 10 s Gain This parameter is used to set the electronic brightness gain A high value electronically increases the brightness of the captured image...
Страница 21: ...e g a letter in a numerical field the background is highlighted red and the value is not sent to the reader If a value outside the validity range is entered the background is also highlighted red The...
Страница 22: ...edge level Trigger signal edge The sensor responds to edges i e signal changes rising falling edge that are triggered by a photoelectric sensor Figure 7 1 Pulse diagram trigger rising edge Triggers f...
Страница 23: ...AC400 ODT MAC401 ODT MAC403 Operation 216677 2012 05 23 Figure 7 2 Pulse diagram trigger rising edge and level Figure 7 3 Decoder settings General Options Trigger Decoder Result Trigger Trigger rising...
Страница 24: ...oding Suppress unsuccessful read RS232 TCP IP Specifies whether the output of the signal or output string from an unsuccessful read should be suppressed activated or not suppressed deactivated Machine...
Страница 25: ...er the burst is stopped after a good reading If the burst length is set to infinite the burst does not stop after a good reading Duplicate suppression ms The value range is 0 ms 30000 ms Here enter th...
Страница 26: ...216677 2012 05 26 ODT MAC400 ODT MAC401 ODT MAC403 Operation Figure 7 5 Pulse diagram burst trigger interval Trigger Picture recording Decoder Result Burst length...
Страница 27: ...burst trigger stops if decoding is successful Number of images per burst Specifies the maximum number of images captured in each burst Option of selecting between 2 and 9 Interval between frames Speci...
Страница 28: ...ore than 1 second The table contains placeholders that can be inserted manually or by clicking the mouse At present the following information can be output as part of the output string Code content co...
Страница 29: ...ODT MAC400 ODT MAC401 ODT MAC403 Operation 216677 2012 05 29 Figure 7 7 Menu item processing modes single window Figure 7 8 Tooltip matchcode...
Страница 30: ...ers can be found in the appendix see chapter 9 3 Bad read output Specifies the character string that will be output if decoding was unsuccessful A timeout error will also result in the output of this...
Страница 31: ...ODT MAC400 ODT MAC401 ODT MAC403 Operation 216677 2012 05 31 Figure 7 9 Menu item processing modes multi window Figure 7 10 Tooltip good read message bad read message...
Страница 32: ...if decoding was successful This field uses Tooltip functionality A table appears if the mouse pointer remains over one of the two input fields for more than 1 second see Figure 7 10 on page 31 The tab...
Страница 33: ...tion of minor interference The filter can be enabled or disabled with filter sizes 3 5 7 9 11 Morphological filters module enlargement Morphological filters are frequently used to suppress noise segme...
Страница 34: ...activated simultaneously Rectangular Data Matrix activated You can activate the detection of rectangular Data Matrix codes Module size m Use this parameter to specify the minimum and maximum module si...
Страница 35: ...ODT MAC400 ODT MAC401 ODT MAC403 Operation 216677 2012 05 35 Maxi Code In the Maxi Code tab you are able to define individual modes of the Maxi Code symbology Example...
Страница 36: ...7 In the MicroPDF 417 tab you can either activate or deactivate detection of the MicroPDF 417 code Example PDF 417 In the PDF 417 tab you can either activate or deactivate detection of PDF 417 codes E...
Страница 37: ...to compare the read code with the checksum and then to output the code with the checksum check The other option is to compare the code that has been read with the checksum and then to output the code...
Страница 38: ...the code without the checksum check remove Example Code 39 In the Code 39 tab you can either activate or deactivate detection of the Code 39 code Checksum handling This feature enables you to activat...
Страница 39: ...maller quiet zone Codes with smaller quiet zones are also decoded Example Code 128 In the Code 128 tab you can either activate or deactivate detection of the Code 128 code Permit smaller quiet zone Co...
Страница 40: ...Interleaved 2 of 5 code Checksum handling This feature enables you to activate or deactivate checking of the checksum using one of two options One option is to compare the read code with the checksum...
Страница 41: ...n is to compare the read code with the checksum and then to output the code with the checksum check The other option is to compare the code that has been read with the checksum and then to output the...
Страница 42: ...two options One option is to compare the read code with the checksum and then to output the code with the checksum check The other option is to compare the code that has been read with the checksum a...
Страница 43: ...length Specifies the minimum size of the code that is to be detected Example Industrial Standard 2 of 5 3 bar start stop codes In the Straight 2 of 5 tab 3 bar start stop codes you can either activate...
Страница 44: ...te or deactivate detection of the Trioptic Code 39 code Permit smaller quiet zone Codes with smaller quiet zones are also decoded Example UPC EAN JAN In the UPC EAN JAN tab you can either activate or...
Страница 45: ...um and maximum number of bars in the code Code contents Enter the number range that is to be decoded Direction angle Specify whether the code is to be read in a horizontal or a vertical direction Deco...
Страница 46: ...directional is the standard setting although this means that it will take longer to read the code Australia Post Code with zero FCC DPID activated Activate or deactivate the Australia Post Code with z...
Страница 47: ...nhance OCR recognition This field is recommended if you have selected the pass template Many countries print a pattern behind the OCR code on the ID which prevents the code from being read properly Ho...
Страница 48: ...216677 2012 05 48 ODT MAC400 ODT MAC401 ODT MAC403 Operation...
Страница 49: ...ODT MAC400 ODT MAC401 ODT MAC403 Operation 216677 2012 05 49 The following font types are supported OCR A OCR B MICR E 13B SEMI OCR...
Страница 50: ...dress Assign a new IP address to the sensor using this field Subnet mask Change the subnet mask using this field Gateway Change the gateway using this field TCP IP port for process communication Chang...
Страница 51: ...the upper section of the display the last 6 error images saved in the stationary reader are shown as a preview You can save the images locally in pgm or gif format Saving an image locally 1 Click the...
Страница 52: ...o change the language for the entire operator interface You can navigate to the other tabs Settings Communication and Galleryin the left display area Selecting changing the language 1 Choose one of th...
Страница 53: ...medy ST LED not lit up The power supply is switched off Check whether there is a reason for it being switched off installation or maintenance work etc Switch the power supply on if appropriate ST LED...
Страница 54: ...this case the device does not wait for the next character If ESC is pressed for the first character the device responds with C ESC LF CR Timeout A V1 command character must be input within one second...
Страница 55: ...Error code ECC Data cr lf Meaning Command 1 hex digits The first digit of the command is output fOk 1 decimal digit 0 Ok 1 Error Data unlimited number Data contained in larger smaller characters if da...
Страница 56: ...numbers These values are ignored for the settings Commands 0 to 8 Command A Command Description C D2 D1 D0 0 H H X Flash duration in intervals of 10 s Example 0120H sets the flash duration to 180 s 2...
Страница 57: ...ODT MAC400 ODT MAC401 ODT MAC403 Appendix 216677 2012 05 57 Command C...
Страница 58: ...x 0x00 Filter off 0xXY Filter size in X and Y direction possible values in each case 0x1 to 0x6 extend light areas 0x9 to 0xE extend dark areas 0x1 to 0xE plus offset 0x8 for both dimensions 1 6 or 9...
Страница 59: ...ut 00 Provides the number of saved error images 01 05 CE01 to CE05 display error images 1 to 5 09 Displays the last captured image 10 Displays the last captured image F 00 Reserved F H Sets resolution...
Страница 60: ...eated in the output followed by the values The string is tested for 10D OR 10M with autodetect and it must not be longer than 20 characters 1 0 0 Decoding software version ends with CR LF 3 X X Video...
Страница 61: ...egibility however it is displayed as 20 once entered Selected nonprintable characters and their meaning The null byte ASCII 0 cannot be used Permissible range 01 FF The character itself must be entere...
Страница 62: ...ontent PSTR x y From character x counting starts at 0 with length y length positive Example PSTR 0 5 the first 5 characters of the code are output PSTR E x x characters from the end until the end Exam...
Страница 63: ...center point of the code relative to the top left corner of the image 4 digit numerical value decimal range 0000 9999 unit pixel PCYL Y coordinate of the center point of the code relative to the top...
Страница 64: ...76 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd Co...