Pepperl+Fuchs ODT-MAC40-RD Series Скачать руководство пользователя страница 14

 2

012-

10

14

ODT-MAC40*-*-RD

Installation

5.4

Network configuration overview

Communication with the sensor is carried out via a free Ethernet interface on the 

PC. It is usually an integrated LAN interface.
This interface must be assigned an address (IP address) so that it can establish a 

connection with the sensor.
The various stations in a TCP/IP network are identified via IP addresses. Each IP 

address must only be used once within a subnet. IP addresses are made up of 4 

blocks, each with a three-digit number between 0 and 255 (8 bit), e.g. 

192.168.2.65.

Example:

 IP address 192.168.2.2 with subnet mask 255.255.255.0

A device with these settings can establish direct communication with any IP 

address between 192.168.2.0 and 192.168.2.255. (The first 3 blocks must 

match.)
In TCP/IP networks, fixed IP addresses can be set on the device or they can be 

assigned dynamically by a DHCP server.

The sensor does not support DHCP, i.e. only fixed IP addresses can be 

used.

The Ethernet interface used on the PC to communicate with the sensor must be 

configured in line with the sensor settings. However, one must ensure that the 

sensor IP address is not entered in the PC.

Example:

Sensor setting:

IP 192.168.2.2

Subnet mask 255.255.255.0

LAN interface on the PC:

IP 192.168.2.90

Subnet mask 255.255.255.0

Содержание ODT-MAC40-RD Series

Страница 1: ...ODT MAC40 RD Stationary reading device for Data Matrix Codes FACTORY AUTOMATION MANUAL...

Страница 2: ...erms of Delivery for Products and Services of the Electrical Industry published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its...

Страница 3: ...12 5 2 Mounting 12 5 3 Connecting the device 13 5 4 Network configuration overview 14 5 5 Assigning an IP address to a network connection using Windows XP 15 5 6 Assigning an IP address to a network...

Страница 4: ...a worldwide scale Symbols used The following symbols are used in this manual Handling instructions You will find handling instructions beside this symbol Contact If you have any questions about the de...

Страница 5: ...oped and manufactured under observance of the applicable European standards and guidelines The product manufacturer Pepperl Fuchs GmbH D 68307 Mannheim has a certified quality assurance system that co...

Страница 6: ...e No 50 dated 06 24 07 Danger This symbol indicates a warning about an immediate possible danger In case of ignoring the consequences may range from personal injury to death Warning This symbol indica...

Страница 7: ...d devices are intended to be used only for the identification of objects by means of Data Matrix codes Always operate the device as described in these instructions to ensure that the device and connec...

Страница 8: ...he stationary read device can be configured easily and quickly using a normal web browser via the standard Ethernet interface or a series connection Support is also provided for the mechanical alignme...

Страница 9: ...des Status LED 1 RJ45 Ethernet network socket 2 15 pin D Sub connector 3 Video output VGA 4 Status LED LED color Description Yellow The LED briefly illuminates in yellow after switching on Green The L...

Страница 10: ...or inputs outputs 24 VDC 7 NC Not connected 8 IN2 Input 2 9 OUT1 Good output 10 OUT2 Bad output 11 IN1 Trigger 12 NC Not connected 13 TX RS232 Transmission line RS232 14 RX RS232 Receive line RS232 15...

Страница 11: ...5 Not assigned 6 Receive data 7 Not assigned 8 Not assigned 3 4 5 6 7 8 1 2 Model number Description ODZ MAC CAB VIDEO Video connection cable cylindrical connector 7 pin on SUB D socket 15 pin VGA 2 m...

Страница 12: ...e 5 2 Mounting The read distance differs according to the reader The correct read distance can be found in the technical data for the reader to be installed The straight version is available only upon...

Страница 13: ...ed as follows When delivered the device has a fixed IP address 192 168 2 2 To facilitate communication within the network you must configure your network The configuration data can be found in the net...

Страница 14: ...8 2 65 Example IP address 192 168 2 2 with subnet mask 255 255 255 0 A device with these settings can establish direct communication with any IP address between 192 168 2 0 and 192 168 2 255 The first...

Страница 15: ...ection using Windows XP proceed as follows 1 First select Network Connections 2 Then open the required connection by double clicking on it The Properties dialog box for the relevant connection will op...

Страница 16: ...Enter an IP address which only differs from the sensor IP address in the very last segment 6 Enter 255 255 255 0 as the subnet mask 7 Then confirm your entries on the TCP IP properties page and the LA...

Страница 17: ...a network connection under Windows 7 1 First select Control Panel from the Start menu 2 Select the Network and Sharing Center option 3 In the Network and Sharing Center window select Change adapter se...

Страница 18: ...n 5 Select the Internet Protocol Version 4 TCP IPv4 element from the Properties dialog box by double clicking on it The TCP IP properties dialog box will open 6 Activate Use the following IP address i...

Страница 19: ...the LAN connection properties page to confirm your entries This completes the network configuration and the sensor can be used 5 7 Storage and transport For storage and transport purposes package the...

Страница 20: ...wser Aligning the stationary reader To find the ideal alignment for the device use the two laser diodes in the stationary reader 1 Supply power to the reader via the D Sub connector 2 Adjust the stati...

Страница 21: ...roceed as follows In the input field of a standard web browser enter the IP address of the stationary reading device 192 168 2 2 and confirm this using Return The Settings tab opens as the start page...

Страница 22: ...ghts up green when a device is connected Otherwise it is red Activating live image capture To activate live image capture click the Start Live Modebutton on the right hand side of the display screen T...

Страница 23: ...et the electronic gain A high value electronically increases the brightness of the captured image and can improve the readability of the code considerably in the event of poor ambient conditions Param...

Страница 24: ...equired command in the Command field 3 Click on Send The relevant command will be sent to the sensor where it will be executed Setting Explanation Parameter set Load from flash Use this action to load...

Страница 25: ...ok 3 Follow the instructions on the display The sensor is set to the new address Parameter Explanation IP address Assign a new IP address to the sensor using this field Subnet mask Change the subnet m...

Страница 26: ...the upper section of the display the last five fault patterns saved in the stationary read device are shown as a preview You can save the patterns locally in pgm or gif format Saving a Pattern Locally...

Страница 27: ...entire operator interface Using the buttons on the left hand section of the display you can navigate to the other tabs Settings Communication and Gallery Selecting changing the language 1 Choose one...

Страница 28: ...t lit up The power supply is switched off Check whether there is a reason for it being switched off installation or maintenance work etc Switch the power supply on if appropriate ST LED not lit up The...

Страница 29: ...wait for the next character If an ESC is sent as the first character the device responds with C ESC LF CR Timeout Entering a V1 command character takes one second If no character appears within this...

Страница 30: ...x Bad read 81FAIL FAIL is optional and can be freely selected Command Description C D2 D1 D0 0 H H X Set flash duration in 10 s increments Example 0120H 18 decimal sets the flash duration to 180 s 2 H...

Страница 31: ...wise automatically This flag also affects 0x400 as it switches off continuous reading 0x400 Continuous reading on as long as 0x200 has not been set 9 0 0 H Match code Value Description 0 Match code in...

Страница 32: ...g Important Set the filter parameters first using the command C5xx Value Set Function 0x00 All filters are disabled 0x01 Increase areas erosion dilatation Possible parameterization using C5xx 0x00 Fil...

Страница 33: ...or 255 The automatic gain sweep stops once decoding is successful A X 0 Loading parameters from the flash memory A X 1 Restore factory settings apart from IP parameters A X 2 Reset IP subnet gateway...

Страница 34: ...ix grid Command Description C D2 D1 D0 E Set decoding parameter Parameter D2 specifies the parameter 1 H H Set grayscale threshold D1D0 Value range 0 to 255 factory default setting 32H 50 decimal 3 H...

Страница 35: ...H Mirror option to read mirrored codes Value Effect 0 No mirroring 1 Mirroring 2 Code reading first not mirrored then mirrored 3 Code reading first mirrored then not mirrored B 1 H Inverse option to r...

Страница 36: ...laser pointer 2 on 2 Laser pointer 1 on laser pointer 2 off 3 Laser pointer on Command Description C D2 D1 D0 Command Description C D2 D1 D0 F X X X Exit decoder and change baud rate It is then imper...

Страница 37: ...GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc Twinsburg Ohio 44087 USA Tel 1 330 4253555 E mail sales us pepperl fuchs com Asia Paci...

Отзывы: