![Pepperl+Fuchs IUH-F117-V1-CN Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/pepperl-fuchs/iuh-f117-v1-cn/iuh-f117-v1-cn_manual_1527897037.webp)
IUH-F117-V1-*
Operation
20
13
-0
4
37
7.5.2
Read and Write Parameters
With the read parameter (
RP
) and write parameter (
WP
) configuration
commands, you can read/write the following parameters:
The parameters are generally saved in the read/write head as nonvolatile.
Read Parameters
Command RP reads configuration parameters from the read/write head.
<SystemCode> = U
ASCII
for IUH-*
<ParamTyp> = 2 bytes ASCII
<DataLength> = Length of <Data>, 2 bytes binary
Example:
RP1UE5.00.00 outputs the number of unsuccessful read attempts until status 5.
Write Parameters
Command WP writes configuration parameters to the read/write head.
<SystemCode> = U
ASCII
for IUH-*
<ParamTyp> = 2 bytes ASCII
<DataLength> = Length of <Data>, 2 bytes binary
Example:
WP1UE5.00.01.05 sets the number of unsuccessful read attempts to status 5 on 5
attempts.
Abbre-
viation
Page
Parameter is
readable/writeable
IUH-F117-V1-
EU
CN
US
AP
See "Antenna Polarization AP" on page 38
Readable/writeable
PT
See "Transmission Power "Power Transmit" PT" on page 38
Readable/writeable
CD
See "Channel Dense Reader Mode CD (EU version
only)" on page 39
Readable
/writeable
-
-
RD
See "Reset to Default, RD" on page 39
Writeable
TA
See "Number of Attempts "Tries Allowed" TA" on page 40
Readable/writeable
E5
See "Number of Unsuccessful Attempts until Status
5 "Enhanced Status 5" E5" on page 40
Readable/writeable
MB
See "Memory Module for Tag Accesses to the
Readable/writeable
Command: RP <ChanNo> <SystemCode> <ParamTyp> <DataLength> <CHCK> <ETX>
Response:
<Status> <ChanNo> <Data> <CHCK> <ETX>
Command: WP <ChanNo> <SystemCode> <ParamTyp> <DataLength> <Data> <CHCK> <ETX>
Response:
<Status> <ChanNo> <CHCK> <ETX>
Содержание IUH-F117-V1-CN
Страница 49: ...IUH F117 V1 Appendix 2013 04 49...