IDM-Z2-160-D-J2-SU-* System Structure 4
Overview of the complete system structure 4: Wired 1-D or 2-D handheld scanner IDM-Z2-x61-
M-* connected via base station/charger to the power module and the USB Ex i interface "3"
(Module A or B) of the VisuNet GXP.
Figure 4.5
Requiered components:
•
VisuNet GXP system with interface "3"
•
DATL-IDM-DB-S-XX00-N0 connection cable VisuNet GXP interface
•
CBL-IDMx61-B-Jx-S-S07-N0 base station connection cable
•
Bluetooth barcode reader (1-D or 2-D)
•
IDM-Z2-x61-B-J2-BT-N0 Base station
•
HOLDER-BRACKET-XX00-IDMx61-B-N
Description
The Bluetooth handheld barcode reader is designed to be used in explosion-hazardous areas.
For proper operation in explosion-hazardous areas, an IDM-Z2-x61-B-J-BT-N0 base station,
the permissible RS232 cordsets CBL-IDMx60-D-J1-S* and thethe DATL-IDM-DB-SXX00-N0
connection cablemust be used. An accessory cable DATL-IDM-DB-S-XX00-N0 is required for
a connection to the VisuNet GXP in the AG-XX00 housing via the interface "3" option. This pro
-
vides the housing feedthrough and has a connection socket that fits the scanner connection
cable. The intrinsically safe power supply and data transfer is realized via the CBL-IDMx61-B-
Jx-U-S07-N0 connection cable.
Note
Find details regarding the mechanical installation in the VisuNet FLX system manual.
Z2 Bluetooth Barcode Reader connection to VisuNet GXP via "S3" interface
Note
The installation of the IDM-Z2-x61-B-J2-BT-N0 base station with either the IDM-Z2-161-M-1D-
J2-BT-N-N0, IDM-Z2-161-M-1D-J2-BT-P-N0 or IDM-Z2-261-M-2D-J2-BT-N-N0 Barcode
Reader to the integrated barrier of the VisuNet GXP requires the optional interface "3". Please
refer to the VisuNet GXP Datasheets (Module A and B) for further information regarding the
interfaces.