![Pepperl+Fuchs IDM-Z2-161-M-1D-J2-BT-N-N0 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/pepperl-fuchs/idm-z2-161-m-1d-j2-bt-n-n0/idm-z2-161-m-1d-j2-bt-n-n0_manual_1527615015.webp)
IDM-Z2-161-M-1D-J2-BT-N-N0, IDM-Z2-161-M-1D-J2-BT-P-N0, IDM-Z2-261-M-2D-J2-BT-
2
02
2-
01
15
Description:
The Bluetooth
®
barcode reader is designed to be used in explosion-hazardous areas Zone
2/22. For proper operation in explosion-hazardous areas, the permissible RS-232 cordsets
CBL-IDMx60-D-J1-S* must be used. The intrinsically safe power supply and data transfer are
realized via this cable. The connection in this structure uses the supply cable SK-IDM-Z2-J2-
5M-S-N which is connected to the communication interface.
The RS-422 interface of the host PC is located in the non-explosion-hazardous area. Data
communication is via the RS-422 interface, while the handheld barcode reader is powered by
the additional power supply. The power is transferred within the supply cable SK-IDM-Z2-J2-
5M-S-N into intrinsically safe power. To overcome long communication distances up to 200 m,
an optional GR.TJE.13.13.09.B-S0008 connection box can be installed.
#70142693 HOLDER-BRACKET-
SK-IDM-Z2-N0
Bracket to wall-mount SK-IDM-Z2-J2-*
barrier
- Material: Stainless steel AISI 304
(1.4301)
- NOTE: Barrier not included!
#70142118 GR.TJE.13.13.09.B-
S0008
Enclosure material: glass fiber reinforced
polyester (GRP)
Enclosure size (HxWxD): 130 x 130 x 130
mm
Finish: inherent color black
nclosure cover: fully detachable
Gasket: foamed silicone
Explosion protections gas: Ex eb IIC T4
Gb
Explosion protection dust: Ex tb IIIC
T135
°
C Db
Ambient temperature: -40
°
C to +60
°
C
Degree of protection: IP66
Certification: ATEX, IECEx & UKEx (oth
-
ers on request)
Equipped with: 7x MUT2.5, labeled "1-7"
2x MUT2.5-PE, labeled "PE"
1x M20
–
top centered
1x M16 (connection barcode reader
cable)
–
bottom centered
1x Blind plug or Cable gland M16 left side
1x Blind plug or Cable gland M20 right
side
Item no.
Product Name
Description
Photo
Note
It is the customer's responsibility to ensure that the voltage applied at the front arrives at the
rear of the unit.