Figure 4.14
Intrinsically safe terminal compartment of the supply module after removing the connector
connection cores
4.3
Base connection line RS232
Assignment of pre-installed base connection cable to supply module (RS232)
Direct connection of the base station without a plug/coupling to the
supply module with RS232 interface
The base station can be connected directly to the supply module without using the blue base
connection cable.
The assignment of the serial base station cable CBL-IDM-x61* is outlined in the following table.
Figure 4.15
Connection layout
Assignment of pre-assembled connec-
tion coupling
Supply module terminal compartment
Pin
Core designation
Designation
Number
3
3
RxD
X9
GND
X10
PE
X11
2
2
GND
X12
1
1
+UB
X13