0
0
0
0
-0
0
14
IDM-Z1-161-M-1D-J1-BT-N-N0, IDM-Z1-161-M-1D-J1-BT-P-N0, IDM-Z1-261-M-2D-
J1-BT-N-N0
Figure 3.5
System structure 3 - scanner with a base station in the safe area/Bluetooth option VisuNet
GXP
Description:
The Bluetooth handheld scanners can be used alone in explosion-hazardous areas; the base
station and charging cradle can be installed in the safe area.
Depending on the application, communication with a Bluetooth-enabled operator workstation
(e.g., VisuNet GXP) can be realized (option 1). In this case, it is possible to use the IDMx61-C-
N0-BT-N0 charging cradle in the safe area to charge the scanner.
Instead of just the charging cradle, the non-explosion hazardous area base station IDMx61-B-
N0-BT-N0 can be used (option 2).
In this scenario a Host PC needs to be connected to the Non-Ex Base Station or Charger to
realize the datatransfer. RS232 and USB cables are available in different lengths. The SUB-D9
connector of the RS232 needs additionally be connected to the PSU-IDMx61-BC-N0-N0 Non-
Ex AC/DC Power Supply.
If USB 3.0 is available in your host device, both battery charging and regular operation can be
supported by the USB Bus Power without using external power supply. If you want to use this
feature, set the USB bus power switch to
“
ON
”
. Then connect the cradle and host device via an
USB cable.
If only USB 2.0 is available in your host device the external power supply is necessary as a
power source, because the power supplied from USB 2.0 is not enough to support both battery
charging and regular operation simultaneously.