Installation
You must establish a low resistance and low inductance connection between the
shields and ground so that the shielding is not interrupted through the metal
enclosure. The complete electronics system and all routed cables are therefore
located within a Faraday cage.
5.3
Mounting
If you would like to the mount the IDENTControl Compact to a DIN mounting rail,
we recommend using mounting aid ICZ-MH05-SACB-8.
Set the rotary switches before mounting the IDENTControl Compact (see chapter
6.4).
5.4
Device connection
Electrical connection using plug connectors makes installation simple.
5.4.1
Power Supply
Connect the power supply using an M12 connector. A plug with the following pin
assignment is located on the enclosure:
Compatible connecting cable see chapter 4.2.2.
Note!
The rotary switches used to select the device address are located on the
underside of the IDENTControl Compact. These rotary switches are no longer
accessible once the IDENTControl Compact is installed.
1
+ 24 V
2
NC
3
GND
4
NC
4
1
3
2