![Pepperl+Fuchs IC-KP-B17-AIDA1 Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/pepperl-fuchs/ic-kp-b17-aida1/ic-kp-b17-aida1_manual_1527930114.webp)
2014-
02
114
Appendix A
Sending a write command as an implicit command
Ele-
ment
Implicit
telegram
Use
Contents Description
1
Byte 0
Command code
40h
Command
SW
(Single write double words)
Byte 1
Number of double words/
Channel/Toggle bit
10h
1 double word = 4 bytes
Element defines the channel.
Toggle bit = 0
Byte 2
Address of double word
(high byte)
00h
Start address = 0
Byte 3
Address of double word
(low byte)
00h
Start address = 0
Byte 4
Data
00h
1. Byte data
Byte 5
Data
01h
2. Byte data
Byte 6
Data
02h
3. Byte data
Byte 7
Data
03h
4. Byte data
2
Byte 8
Command code
40h
Command
SW
(Single write double words)
Byte 9
Number of double words/
Channel/Toggle bit
10h
1 double word = 4 bytes
Element defines the channel.
Toggle bit = 0
Byte 10 Address of double word
(high byte)
00h
Start address = 0
Byte 11 Address of double word
(low byte)
00h
Start address = 0
byte 12 Data
10h
1. Byte data
Byte 13 Data
11h
2. Byte data
Byte 14 Data
12h
3. Byte data
Byte 15 Data
13h
4. Byte data
3
Byte 16
...
Byte 23
00h
No commands are transmitted
to channel 3.
4
Byte 24
...
Byte 31
00h
No commands are transmitted
to channel 4.