EXTA4-* Keyboard
Installation and Commissioning
4.6
Installation Instructions for Hazardous-Location EMC Cable
Glands
Power supply cables for the Ex e Ethernet and the RS-485 or TTY Ex e data interface, the Ex i
keyboard, and the Ex i scanner must be shielded to ensure sufficient immunity to interference
(EMC). Connect the cable shielding to the VisuNet RM/PC according to the following installa-
tion instructions:
Step 1
•
Isolate the cable.
•
Expose the braid.
•
Remove the braid and insulation little by
little.
•
With thin cables, the braid can be folded
back over the insulation sheath.
•
Insert the cable into the gland until the
braid reaches the contact point.
•
Tighten the cable gland.
Step 2
•
Guide the cable through the lock nut.
•
Guide the cable into the terminal insert.
•
Fold the braid over the insert.
•
The braid must overlap the O-ring by
about 2 mm