Product Description
2
0
2
0
-0
9
9
If you use the "IO-Link Offline Parameterization Tool" software package, have active Internet
access, and have connected your device via the Fuchs IO-Link USB master, you can
integrate the IODD directly into the IO-Link Offline Parameterization Tool via the "IODD DTM
Configurator."
The device description file (IODD) required for integration in an IO-Link system and for the
parameterization and diagnosis is available online. Visit www.pepperl-fuchs.com and navigate
to the relevant product page for the ENA***TL-**IO**.
Online Parameterization
When commissioning machines and plants, you must integrate master and IO-Link devices into
the appropriate control environment. Depending on the components used, different software is
required
You can configure and parameterize the devices using an IO-Link configuration tool. During
operation, you can check the parameters for the IO-Link devices, read, and monitor the status
and diagnostic data. IO-Link data is integrated into an application program using function
blocks.
2.2
LED Indicators
The device has a green/yellow LED with the following characteristics:
Localization Function
To easily locate a device within a plant, you can activate / deactivate the localization function for
the LED on the device via IO-Link. Once this function has been activated, the LED will pulsate
and flash, so that the device can be easily detected within a plant.
After isolating the device from the voltage supply, the LED will stop flashing as standard.
The flashing function is activated via parameter "0x7F" (localization display) to value 1. It is
possible to activate this function via offline parameterization in the
diagnostic
menu, "Service
function" function, indication setting set to "Localization Indication."
Color
Description
Off
Insufficient supply voltage, incorrect cabling
Green
•
Permanently on = supply voltage is OK
•
Short flashes on and off = IO-Link communication is active
Green
Pulsating flashing = localization function
Table 2.1