37
0
2
.05.
2016
CC-Link Gateways
Diagnostics
8.2
Diagnostics on the host controller
All the diagnostics information is also provided on the host controller.
8.2.1
Diagnostics through process data
Diagnostics through the process data provides a very simple means of incorpora-
ting diagnostics information into the controller program and displaying it on a con-
trol panel.
For useful diagnostics we recommend use of the following options:
8.2.1.1
Diagnosing the AS-i circuits
Flags + Fault Detector (see chap. 6.1.1).
When a configuration error is reported, e.g. because an AS-i slave has failed, the
AS-i master continues to communicate with the remaining slaves. In many cases
however a good and simple solution is to terminate running of the PLC program in
case of a configuration error.
8.2.1.2
Diagnosing the Safety Monitor
Safety diagnostics in the Input Data Image
Diagnostics for the states of the safety AS-i in- and outputs. To obtain diagno-
stics information for a safety AS-i output the associated diagnostics slave
address must be incorporated (see paragraph <A>).
Fieldbus Bits and Safety Status
User-specific diagnosing and diagnosing the states of the release circuits
(see chap. 6.1.4 and chap. 6.1.3)