background image

Fuchs Quality

Download our latest policy here:

www.pepperl-fuchs.com/quality

www.pepperl-fuchs.com

©

 Fuchs 

·

 Subject to modifications

Printed in Germany  / DOCT-7025

Содержание ARS1-B2-IC08-1

Страница 1: ...ARS B2 IC Ethernet APL Rail Field Switch Hardware Manual ...

Страница 2: ...rsion as well as the supplementary clause Expanded reservation of proprietorship Worldwide Pepperl Fuchs Group Lilienthalstr 200 68307 Mannheim Germany Phone 49 621 776 0 E mail info de pepperl fuchs com North American Headquarters Pepperl Fuchs Inc 1600 Enterprise Parkway Twinsburg Ohio 44087 USA Phone 1 330 425 3555 E mail sales us pepperl fuchs com Asia Headquarters Pepperl Fuchs Pte Ltd P F Bu...

Страница 3: ...ription 6 2 1 Overview and Application 6 2 2 Type Codes 6 2 3 Components and Dimensions 8 2 4 Accessories 9 2 5 Scope of Delivery 12 2 6 Technical data 12 3 Installation 15 3 1 General Installation Information 15 3 2 Mounting and Dismounting 15 3 3 Connection Assignment 20 3 4 Grounding Shielding 22 4 Operation 24 4 1 Operating Elements 24 ...

Страница 4: ...ion certificate EU declaration of conformity Attestation of conformity Certificates Control drawings Additional documents 1 2 Target Group Personnel Responsibility for planning assembly commissioning operation maintenance and dismount ing lies with the plant operator Only appropriately trained and qualified personnel may carry out mounting installation com missioning operation maintenance and dism...

Страница 5: ... in descending order as fol lows Informative Symbols Action This symbol indicates a paragraph with instructions You are prompted to perform an action or a sequence of actions Danger This symbol indicates an imminent danger Non observance will result in personal injury or death Warning This symbol indicates a possible fault or danger Non observance may cause personal injury or serious property dama...

Страница 6: ... are rated intrinsically safe Ex ic IIC for Zone 2 and Zone 22 mount ing The spurs are compatible with the Ethernet APL port profile SPCC 2 RJ45 and 2 SFP Ethernet interfaces permit the connection to industrial Ethernet networks like PROFINET or EtherNet IP 2 of the 4 ports may be used in ring configuration Fiber optic small form factor pluggable SFP transceivers are available as accessories Prod ...

Страница 7: ...her details Contact your Pepperl Fuchs representative to check the availability of individual product ver sions Order designation Number of Ethernet APL spur connec tions Terminal pluggable Screw terminal Spring terminal ARS1 B2 IC08 1 8 x ARS1 B2 IC08 2 8 x ARS1 B2 IC16 1 16 x ARS1 B2 IC16 2 16 x ARS1 B2 IC24 1 24 x ARS1 B2 IC24 2 24 x Table 2 1 ...

Страница 8: ...10 11 6 7 Dimension a DIN Rail Mounting 1 Year of production 2 Serial number 3 PA connection to equipotential bonding 4 Slot for separation wall 5 MAC ID 6 LED S1 Sn status spur ports S1 Sn 7 Connectors for intrinsically safe spurs S1 Sn 8 Ethernet port P1 9 Ethernet port P2 10 Ethernet SFP port P3 11 Ethernet SFP port P4 12 LED LNK CHK P1 P4 communication status LED P1 P4 13 Connector for auxilia...

Страница 9: ...mber 3 PA connection to equipotential bonding 4 Slot for separation wall 5 MAC ID 6 LED S1 Sn status spur ports S1 Sn 7 Connectors for intrinsically safe spurs S1 Sn 8 Ethernet port P1 9 Ethernet port P2 10 Ethernet SFP port P3 11 Ethernet SFP port P4 12 LED LNK CHK P1 P4 communication status LED P1 P4 13 Connector for auxiliary power and status indication output 14 LED STATUS status switch 15 Res...

Страница 10: ...plies with 100BASE FX Transfer rate 100 Mbit s Reach length of up to 2 km LC duplex connector Multi mode fiber with 1310 nm Complies with a Class 1 laser product in accordance with EN 60825 1 ACC PC 45 RJ45 protective covers packing unit 10 pieces ACC PC SFP SFP protective covers packing unit 10 pieces ACC ARS SW separation walls packing unit 2 pieces ACC ARS WMK Wall mounting kit Table 2 2 Order ...

Страница 11: ... product in accordance with EN 60825 1 For further SFP transceiver versions contact your Pepperl Fuchs sales representative Protective Cover for RJ45 Sockets Figure 2 5 To protect unused RJ45 sockets against dust or unintentional harm protective covers are pro vided Protective Cover for SFP Sockets Figure 2 6 To protect unused SFP sockets against dust or unintentional harm protective covers are pr...

Страница 12: ...spur terminals Wall Mounting Kit Figure 2 8 A wall mounting kit is provided as an accessory The kit includes 2 brackets The factory installed DIN mounting rail clamps must be removed before installing 2 5 Scope of Delivery The rail field switch is delivered with mounting brackets for DIN mounting rail 2 6 Technical data Depending on the mounting position of the rail field switch and the use of SFP...

Страница 13: ...ARS B2 IC Product Description 2021 03 13 Figure 2 9 Figure 2 10 Horizontal Mounting Position Vertical Mounting Position ...

Страница 14: ...21 03 14 ARS B2 IC Product Description Mounting position Use of SFP transceivers Ambient temperature Horizontal No 40 C 70 C Horizontal Yes 40 C 65 C Vertical No 40 C 55 C Vertical Yes 40 C 55 C Table 2 3 ...

Страница 15: ...phere If the device is installed in Zone 2 without mounting it in a sufficiently suitable surrounding enclosure gas dust water or other external interferences can cause the live device to spark The sparks can ignite the surrounding potentially explosive atmosphere Mount the device in a surrounding enclosure that complies with the requirements for surround ing enclosures according to IEC EN 60079 0...

Страница 16: ...e electronics onto the DIN mounting rail 3 Move the top hook over the upper end of the DIN mounting rail until the locking mechanism engages Dismounting DIN mounting rail Figure 3 2 1 Use a slot head screwdriver and push down the locking mechanism to release the device 2 Tilt the device downwards to free it from the DIN mounting rail 1 2 3 1 2 ...

Страница 17: ...g bracket remove the factory installed DIN mounting rail clamps To remove the DIN mounting rail clamps loosen 3 screws each clamp To remove the adapter loosen 2 screws each adapter Figure 3 4 Note When using product version with 8 Ethernet APL spur connections only 1 bracket is needed 1 Screws for DIN mounting rail clamp 2 TX20 screws for adapter 1 2 1 Screw 1 ...

Страница 18: ...sion hazard from sparking when using operating elements Using operating elements in a potentially explosive atmosphere can cause sparks that can ignite the surrounding atmosphere While power is on do not insert and remove SFP transceivers When installing or removing SFP transceivers make sure that power is removed Only use operating elements e g switch slider button etc in the absence of a potenti...

Страница 19: ...arance distance of 50 mm between the non intrinsically safe circuits and intrinsi cally safe circuits install the separation walls Figure 3 5 1 Press the separation walls into the provided slots on the front of the switch 2 Make sure that they are locked in place Danger Explosion hazard from wrong separation distances If you do not observe the minimum separation distances between intrinsically saf...

Страница 20: ...ductor When using stranded conductors crimp wire end ferrules on the conductor ends Use only one conductor per terminal When installing the conductors the insulation must reach up to the terminal Observe the tightening torque of the terminal screws Danger Explosion hazard from connection damage Manipulating connections outside of the specified ambient temperature range can lead to material damage ...

Страница 21: ...R A and PWR B Figure 3 6 Screw terminal Figure 3 7 Spring terminal The switches must be supplied with a DC voltage Un 20 V 60 V that meets the require ments for safety extra low voltage SELV or protective extra low voltage PELV and not exceed a maximum voltage of 60 V DC even under fault condition At the power terminal the cross section of the cables must be chosen in accordance with the maximum f...

Страница 22: ...This can ignite the surrounding potentially explosive atmosphere Ground the device Observe the grounding requirements for type of protection Ex i according to IEC EN 60079 14 Ensure that external ground connections exist are in good condition and are not damaged or corroded Caution Risk of electric shock or property damage from inadequate grounding If you fail to connect all metal parts of the dev...

Страница 23: ...l PA The shields of the connected field devices must be connected to local earth Grounding the Ethernet Copper Cable The Ethernet cable is directly connected to the grounding terminal PA through the RJ45 con nector 1 Phillips head screw M4 x 16 mm 2 Flat washer M4 3 Spring washer 4 Cable lug 5 Flat washer M4 6 Flat washer M4 1 2 3 4 5 6 Warning Dangerous atmospheres and plant damages due to commun...

Страница 24: ... switch to Pep perl Fuchs STATUS Status of the switch Off Good Blue on Maintenance required See note Red flashing Out of specifica tion See note Red on Failure See note LNK CHK P1 P4 Status of the Ethernet ports Off No communica tion link estab lished Green on Communication link established Green flashing Communication link activity Red flashing Check function See note S1 Sn Status of the spurs Of...

Страница 25: ...upply is less stressed during the start up phase and its expected useful lifetime is increased Fold Back Characteristics of the Spur Short Circuit Current Limitation If a spur short circuit occurs the spur current is switched off quickly When the short circuit cur rent has been cleared the spur current returns If multiple simultaneous short circuit currents occur the current management system mini...

Страница 26: ...Pepperl Fuchs Quality Download our latest policy here www pepperl fuchs com quality www pepperl fuchs com Pepperl Fuchs Subject to modifications Printed in Germany DOCT 7025 ...