Installation
2
0
1
5
-0
5
17
3.
Connect the other end of the ground cable to adjacent metal components
(e.g., mounting base, frame, etc.).
The device is now grounded.
Establishing the Network
The M12 plug (D coded) on both devices features the standard assignment for
Ethernet. The optical data coupler automatically locates transmitting and
receiving lines (Auto-MDIX), meaning there is no need to use a crossover cable.
To connect the device to a network, proceed as follows:
1.
Plug the prepared network cable with the 4-pin M12 plug into the socket pro-
vided on the rear of the housing.
2.
Screw the cap nut onto the connector as far as it will go. This ensures that the
power cable cannot be inadvertently pulled out.
3.
Now connect the network cable to the network connection provided for this
purpose.
The device is now ready for operation.
5.4
Storage and Transport
For storage and transport purposes, package the unit using shockproof
packaging material and protect it against moisture. The best method of protection
is to package the unit using the original packaging. Furthermore, ensure that the
ambient conditions are within allowable range.
Note!
The Ethernet cable must be of CAT5 quality as a minimum.
Unshielded cables (UTP) are not suitable for maintaining immunity.